3.8 PROGRAMMING THE P.C.B.
The boiler is prepared for possible programming
of several operation parameters. By modifying
these parameters as described below, the boiler
can be adapted according to specific needs.
Attention:
If the international language is to be
restored (A1) see the indications described in
Par. 2.7 (Customisations menu - M3).
By pressing the button "D" it is possible to access
the main menu, divided into three main parts:
- Information“M1” (See “User” Chapter)
- customisations “M3” (See “User” Chapter)
- “M5” configurations, menu reserved for the
technician and for which a password is required.
To access programming, press button “D”, turn
the central heating temperature selector switch
(3) and scroll through the menu items until
reaching “M5”, press button “D”, enter the pass-
word and set the parameters according to your
requirements.
Listed below are the items in the“M5” menu
with default parameters and possible options
indicated.
By turning the central heating temperature se-
lector switch (3) scroll through the menu items.
By pressing button “D” access the various levels
of the menu and the choice of parameters is
confirmed. Press button “C” to go back one level.
(The first item of the various options that appears
inside the parameter is that selected by default).
M5 menu
(password must be entered)
1st Level
2nd Level
Options
Description
Default value
Value
set
by the
technician
P50
25
÷
50
Set the boiler power in the ignition stage. The value is in percentage with respect
to parameter P62
(See par. 3.5)
P53
P53 1
Identifies the power of the boiler on which the P.C.B. is installed
P53 1 = Not used
P53 2 = 26 kW
P53 3 = 32 kW
Equal to boiler
power
Equal to
boiler
power
P53 2
P53 3
P54
P54. 1
Displays the temperature read on the domestic hot water probe on entry to the
boiler
-
-
P54. 2
Displays the temperature read on the domestic hot water probe on exit from the
boiler
-
-
P54.3
Displays the temperature read on the return probe
-
-
P54.4
Not used on this boiler model
-
-
P55
Displays the central heating flow temperature at which the boiler functions,
calculated by the controls active on the system heat adjustment
-
-
SERVICE
P57
AUTO
- DELTA T = 0:proportional head (see parag. 1.23)
- DELTA T = 5
÷
25 K: constant ∆T (see par. 1.23)
Note:
after selecting DELTA T adequate to the requirements, maximum (Vmax)
and minimum (Vmin) circulating pump speed may be selected (adjustable from
100% to 75%).
AUTO
0
FIX
Fixed circulator pump speed (adjustable between 100% and 75%)
P62
4000 ÷ 5900
Set the maximum output depending on the domestic hot water, setting the speed
of the fan (in RPM)
(See par. 3.5)
P63
900 ÷ 1500
Set the minimum output depending on the domestic hot water, setting the speed
of the fan (in RPM)
(See par. 3.5)
P64
≤ P62
Set the maximum output depending on room heating. The value must be less
than or equal to P62
(See par. 3.5)
P65
≥ P63
Set the minimum output according to room heating. The value must be greater
than or equal to P63
(See par. 3.5)
P66
P66/A
Without the external probe (optional) it defines the minimum flow temperature.
With the external probe present it defines the minimum flow temperature corre-
sponding to operation with maximum external temperature (see graph Fig. 1-7)
(it can be set between 20°C and 50°C)
N.B.:
to continue one must confirm the parameter (press “D” or exit adjustment
“P66” by pressing “C”)
20°C
P66/B
Without the external probe (optional) it defines the maximum flow tempera-
ture. With the external probe present it defines the maximum flow temperature
corresponding to operation with minimum external temperature (see graph Fig.
1-7) (it can be set between 50°C and 85°C)
N.B.:
to continue one must confirm the parameter (press “D” or exit adjustment
“P66” by pressing “C”)
85°C
P66/C
With the external probe present it defines at which minimum external tempera-
ture the boiler must operate at the maximum flow temperature (see graph Fig.
1-7) (can be set between -20°C and 0°C)
N.B.:
to continue one must confirm the parameter (press “D” or exit adjustment
“P66” by pressing “C”)
-5°C
P66/D
With the external probe present it defines at which maximum external tempera-
ture the boiler must operate at the minimum flow temperature (see graph Fig.
1-7) (can be set between 5°C and +25°C)
N.B.:
to continue one must confirm the parameter (press “D” or exit adjustment
“P66” by pressing “C”)
25°C