59
STHCkW ed 04/09
HERCULES Condensing Export
Technical Documentation
Technical Documentation
Combustion parameters.
G20
G30
G31
Supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
HERCULES Condensing 26 2 E
Gas nozzle diameter
mm
5,70
4,10
4,10
Flue flow rate at nominal heat output
kg/h
43
39
43
Flue flow rate at min heat output
kg/h
8
7
8
CO
2
at Nom Q./Min.
%
9,40 / 8,90
12,00 / 11,80
10,60 / 10,20
CO with 0% O
2
at Nom Q /Min.
ppm
200 / 7
670 / 11
270 / 7
NO
X
with 0% O
2
at Nom Q /Min.
mg/kWh
57 / 25
187 / 86
69 / 41
Flue temperature at nominal output
°C
78
86
79
Flue temperature at minimum output
°C
73
82
75
HERCULES Condensing 32 2 I / HERCULES Condensing ABT 32 2 I
Gas nozzle diameter
mm
WITHOUT
6,00
6,00
Flue flow rate at nominal heat output
kg/h
52
47
53
Flue flow rate at min heat output
kg/h
12
11
12
CO
2
at Nom Q./Min.
%
9,40 / 8,90
12,30 / 11,90
10,50 / 10,30
CO with 0% O
2
at Nom Q /Min.
ppm
206 / 9
640 / 8
190 / 8
NO
X
with 0% O
2
at Nom Q /Min.
mg/kWh
83 / 43
276 / 89
99 / 54
Flue temperature at nominal output
°C
73
82
74
Flue temperature at minimum output
°C
64
72
66
Содержание Hercules Condensing 26 2 E