18
If the switch is pressed during normal operation, the control port IP address, mask and gateway
are restored to the following factory default settings:
IP Address: 192.168.1.30
Subnet Mask: 255.255.255.0
Gateway:
192.168.1.1
The
STAT
front panel indicator will change colors for about 3 seconds to acknowledge the
change. Note that this operation
does not
disturb the encoding function or the streaming
Ethernet ports (i.e., it is not service-affecting). The IP addresses of the streaming ports may be
also automatically changed if they are in the same subnet as the control IP address above.
If you press and hold this switch when the unit is powered off, and then power up the unit while
holding the switch, the following actions will be performed:
The control IP address, mask and gateway are reset to the factory defaults as described
above.
The unit configuration is cleared.
The unit reverts to the factory-installed firmware.
As before, the
STAT
LED will temporarily change color to acknowledge the command. When it
changes color, you can release the switch. You can use this feature in the unlikely event of a
corrupted firmware upgrade or a corrupted configuration.