2  Mode of Operation

2.1  Measurement value collection with pre-check, average value and filtering

TRIME-GW Line measures internally at a very high rate of measurements per second and issues the resulting 

measurement value at a cycle time of up to 200 milliseconds at the analogue output. Within this cycle time 

of 200 milliseconds a probe-internal pre-check of the moisture values is included. Only plausible and physically 

 pre-averaged measurement values are used for the further data processing. This increases reliability and stability 

of the measurement output at the interface of the probe.
In the 

Measurement Mode CS

 (Cyclic-Successive), an average value is not accumulated, and the cycle time here 

is 200 milliseconds. In the 

Measurement Mode CA and CF

 (Average), not the momentarily measured individual 

values are directly issued, but an average value is accumulated via a variable number of measurements in order 

to filter out temporary variations. These variations can be caused by inhomogeneous moisture distribution of 

the material. The delivery scope of TRIME-GW Line includes suited parameters for the averaging period and a 

 universally applicable filter function deployable for currently usual applications. The time for the average value 

accumulation, as well as various filter functions, can be adjusted and customized for special applications.

2.2  Temperature Measurement 

A temperature sensor is installed on one stay bar of the 1-rod probe which establishes the measurement of the 

material temperature. The temperature can optionally be transmitted at the analogue output 2. 

2.3  Temperature compensation when working at high temperatures

Because the TRIME-GW Line measurement transformer works in other temperature ranges as the 1-rod-probe 

inside the dryer, it is necessary to compensate the electronic separately from the 1-rod-probe. TRIME-GW Line 

offers two possibilities for temperature compensation.

A) Temperature compensation of the internal TRIME-electronic 

Despite the TRIME-GW Line electronic shows a generally low temperature drift, it is necessary to compensate a 

temperature drift in applications for measuring moisture inside a grain dryer. With this method of  temperature 

compensation, a possible temperature drift of the TRIME-electronic can be compensated. For standard  applications 

in grain drying the compensation parameter is pre-set to TempComp = 0.2. For special applications it could be 

necessary to adjust this parameter. But it is to consider that it is necessary to make a Basic-Balancing of the 

 TRIME-GW Line in air and dry glass beads if the parameter TempComp is changed to another value. The  parameter 

TempComp can be changed with the software tool SONO-CONFIG, in the menu 

"Calibration"

 and the window 

"Temperature-Compensation"

.

B) Temperature compensation for the measured material

Water and special materials like maize, wheat and others, show a dependency of the dielectric permittivity when 

using TRIME-GW Line at high temperature ranges. The dielectric permittivity is the raw parameter for measuring 

water content with TRIME-GW Line. If special materials show this temperature drift, it could be necessary to use 

a more elaborate temperature compensation. TRIME-GW Line offers the possibility to set special  temperature 

 compensation parameters for every calibration curve Cal1 of Cal15 (see chapter “Selection of the individual 

 calibration  curve”). 

2.4  Analogue Outputs 

The measurement values are transmitted as a current signal via the analogue output. With the help of the service 

 program 

SONO-CONFIG

, the TRIME-GW Line can be set to the two versions for 0..20mA or 4..20mA. Furthermore, 

it is also possible to variably adjust the moisture dynamic range e.g. to 0-10%, 0-20% or 

0-50%

. For a 0-10V DC 

voltage output, a 500R resistor can be installed in order to reach a 0..10V output.

Содержание TRIME-GW Series

Страница 1: ...Manual TRIME GW Line More information www imko de Moisture Sensor Experts...

Страница 2: ...oisture probe You may contact IMKO directly to after exploring your local contact We look forward to helping you For warranty claims please contact your local dealer distributor or service center The...

Страница 3: ...allation on a steel girder with HEA profile 12 4 3 Carrier plate dimensions for 120mm steel girder 13 4 4 Installation of two carrier plates very close to each other 15 5 Initial operation and adjustm...

Страница 4: ...ue outputs of the SONO probe 31 7 4 Configuration of Measure Mode 32 7 5 Setting the precision of a single value measurement cycle 33 7 6 Test run in the respective Measurement Mode 33 7 7 Measure Run...

Страница 5: ...l capacitive or microwave measuring methods the TRIME technology Time Domain Reflectometry with Intelligent Micromodule Elements offers precise measurement results which means more reliability at the...

Страница 6: ...te the electronic separately from the 1 rod probe TRIME GW Line offers two possibilities for temperature compensation A Temperature compensation of the internal TRIME electronic Despite the TRIME GW L...

Страница 7: ...ME GW Line can be requested via Contact us on www imko de 2 6 The IMP Bus as a user friendly network system With external power supply on site for the SONO probes a simple 2 wire cable can be used for...

Страница 8: ...ways to configure and adjust a SONO probe A Online Configuration via SONO VIEW Withthestand alonedeviceSONO VIEWitispossibletoconfigureSONO probesonlinetoanappropriate operating mode without the need...

Страница 9: ...propriate operating mode like cyclic measurement averaging filtering cumulating and other powerful operating parameters Furthermore it is possible to select a calibration curve inside a SONO probe wit...

Страница 10: ...at the sensor The plant must be properly grounded Transparent Transparent Assignment of the 10 pole MIL Plug and sensor cable connections 3 4 Analogue Output 0 10V with a Shunt Resistor With the help...

Страница 11: ...11 4 TRIME GW Line Installation...

Страница 12: ...HEA profile TRIME GW Line is delivered with a carrier plate as U profile This carrier plate can be mounted directly on a steel girder which can be installed in silos or drying chambers IMKO offers th...

Страница 13: ...13 4 3 Carrier plate dimensions for 120mm steel girder...

Страница 14: ...14 Carrier plate dimensions for 4 steel girder...

Страница 15: ...stallation of two carrier plates very close to each other Here it is very important that the two long rods have sufficient distance to one another This can be achieved with a spacer between the carrie...

Страница 16: ...ired calibration curve Cal1 Cal15 and with using the button Set Active Calib The finally desired and possibly altered calibration curve Cal1 15 which is activated after switching on the probes power s...

Страница 17: ...17 5 3 Calibration Curves Cal1 to Cal15 Calibration functions with and without temperature compensation...

Страница 18: ...5 Special calibration curve Cal13 Cal14 pre setted after delivery Corn ear of maize 0 5 Special calibration curve Cal15 1 10 tp Radar time and reference calibration for test 5 4 Selection and applicat...

Страница 19: ...ifferent point than in the direct vicinity of the probe are not representative Several samples must be taken directly at the probe and averaged At the start of trial operation the suitable calibration...

Страница 20: ...ied with the calibration coefficients see Chapter Creating a linear calibration curve The desired and possibly altered calibration curve Cal1 15 which is activated after switching on the probes power...

Страница 21: ...But it would be also possible to use a higher point P1 e g 190 7 where a tpAve of 190ps corresponds to a moisture content of 7 The gravimetric moisture content of the material e g 7 has to be determin...

Страница 22: ...dDcanbealsoenteredwithoutaPCwiththemoduleSONO VIEW seemanualSONO VIEW 5 11 Calculation for a non linear calibration curve SONO probes can work also with non linear calibration curves with polynomials...

Страница 23: ...rage value can be set with this parameter CC CH CK Setting of the time for calculation of the trend or expectation value for the Boost Offset function Filter Upper Limit Offset Standard Setting 25 Set...

Страница 24: ...nt Standard Setting 2 values Setting Range 0 10 Unit Measurement Values with 3 single values per second CA CF CK inactive CC CH Number of discarded poor measurement values after the start of a new bat...

Страница 25: ...ly partially filled with material for a longer time i e the material temporarily no longer completely fills the probe measuring field During these periods Lower Limit Keep Time the probe would establi...

Страница 26: ...atch process starts So the PLC has time enough to read in the freezed moisture value of the batch For applications without a PLC the freezed signal of the TRIME GW Line can be used for displaying the...

Страница 27: ...value is freezed at the analogue output until the No Material Delay time of e g 5 seconds has expired and a new batch process starts Start of second batch process After the period of No Material Dela...

Страница 28: ...USB to the USB Port of the PC and the installation will be accomplished automatically Install Software SONOConfig SetUp msi from USB Stick Connection of the SONO probe to the SM USB with 4 wires for...

Страница 29: ...there is no double occupancy of the interfaces In case of a conflict when the serial port or the USB SM has been found in a higher COM port the COM port number can be adjusted manually By double click...

Страница 30: ...isplayed on the screen In the menu Bus and the window Configuration the PC can be configured to an available COMx port with the Baudrate of 9600 Baud 7 1 Scan of connected SONO probes on the serial in...

Страница 31: ...can be selec ted to IMP Bus or RS485 Due to very robust behavior it is recommended to select the IMP Bus 7 3 Set analogue outputs of the SONO probe In the menu Config and the window Analog Output the...

Страница 32: ...ent measurement modes e g for averaging values from several single measurement values for performing a filtering or performing other functions see chapter Measurement mode configuration in this manual...

Страница 33: ...Quick Precise Mode C e g CS CH CF etc Quick and precise TDR pulse search and precise measurement within 350ms Similar to Quick but with a little longer reaction time in process measurements Mode A Mod...

Страница 34: ...for the averaging tpAve Radar time average which corresponds to the respective moisture value By clicking Save the recorded data is saved in a text file in the following path SONO CONFIG exe Pfad MD D...

Страница 35: ...adjusted for the material temperatur sensor which is installed inside the SONO probe In this example a temperature deviation of 5 C is produced by inside self warming of the SONO probe The correction...

Страница 36: ...parameter TempComp can be adjusted for higher temperature ranges up to 120 C for special high temperature version to values up to TempComp 0 75 But it is to consider that it is neces sary to make a B...

Страница 37: ...epends on the used material Repeatability 0 2 b w depends on the measured material Measurement transformer tempera ture range 10 60 C extended range on request Probe temperature range 0 60 C Measuring...

Страница 38: ...out of operation and secured by means of marking before further commissioning In case of doubt the sensor or the measuring system must be sent to the manufacturer or his contractual partner for repai...

Страница 39: ...in following case if you do not use the sensor or the measuring system for an extended period of time before cleaning unpacking or changing the sensor or the measuring system if you are working inside...

Страница 40: ...Contact IMKO Micromodultechnik GmbH Am Reutgraben 2 76275 Ettlingen Germany Tel 49 7243 5921 0 Fax 49 7243 5921 40 info imko de Manual TRIME GW Line 08 2021 www imko de...

Отзывы: