10
Plug-PIN
Sensor Connections
Lead Colour
Lead Colour
A
+12V….24V Power Supply
Red
Red
B
0V Power Supply
Blue
Blue
D
1. Analogue Positive (+) Moisture
Green
Green
E
1. Analogue Return Line (-) Moisture
Yellow
Yellow
F
RS485 A
Weiß
White
G
RS485 B
Brown
Brown
C
(rt) IMP-Bus
Grey/
Pink
Grey/Pink
J
(com) IMP-Bus
Blue/
Red
Blue/ed
K
2. Analogue Positive (+)
Pink
Pink
E
2. Analogue Return Line (-)
Grey
Grey
H
Screen
(is grounded at the sensor. The plant must
be properly grounded!)
Transparent
Transparent
Assignment of the 10-pole MIL Plug and sensor cable connections:
3.4 Analogue Output 0..10V with a Shunt-Resistor
With the help of a shunt resistor with 500 ohm (included in the delivery) 0..10V can be generated from the current
signal 0..20mA, in case the local PLC does not handle the recommended 4..20mA. Therefore the 500 Ohm shunt
resistor should be placed at the end of the line respectively at the input of the PLC. Following drawing shows the
wire connection.
NOTE:
The analogue output of TRIME-GW Line must be set to 0 to 20mA!
Содержание TRIME-GW Series
Страница 1: ...Manual TRIME GW Line More information www imko de Moisture Sensor Experts...
Страница 11: ...11 4 TRIME GW Line Installation...
Страница 13: ...13 4 3 Carrier plate dimensions for 120mm steel girder...
Страница 14: ...14 Carrier plate dimensions for 4 steel girder...
Страница 17: ...17 5 3 Calibration Curves Cal1 to Cal15 Calibration functions with and without temperature compensation...