5
Electronic Pressure Sensor 34D
Operation manual
7503756000000050 05/2019
3. Functions and features
The device monitors the system pressure of machines and installations.
3.1 Applications
Type of pressure: relative pressure
Order number
Measuring range
Permissible
overpressure *
)
Bursting pressure
bar
PSI
bar
PSI
bar
PSI
Pressure sensors with internal thread G¼
34D-P600…
0…600
0…8700
800
11580
2500
36250
34D-P400…
0…400
0…5800
800
11580
1700
24650
34D-P250…
0…250
0…3625
500
7250
1200
17400
34D-P160…
0…160
0…2320
350
5075
1000
14500
34D-P100…
0…100
0…1450
300
4350
650
9400
34D-P040…
0…40
-14,5…580
200
2900
500
7250
34D-P016…
0…16
0…232
85
1225
500
2900
34D-V110…
-1…10
-14,5…145
75
1087
150
2175
34D-V101…
-1…1
-14,5…14,5 10
145
30
450
*
)
With static overload pressure or max. 100 million pressure cycles.
MPa = (measured value in bar) ÷ 10
kPa = (measured value in bar) x 100
Media used must be compatible with the materials specified in the data sheet
Avoid static and dynamic overpressure exceeding the specified pressure resistance by taking
appropriate measures.
The indicated bursting pressure must not be exceeded.
Even if the bursting pressure is exceeded only for a short time, the unit may be destroyed.
ATTENTION: Risk of injury!
Pressure Equipment Directive (PED):
The units comply with the Pressure Equipment Directive and are designed and manufactured for
group 2 fluids in accordance with the sound engi-neering practice. Use of group 1 fluids on
request!