-23-
10
Remove the nuts and washers from the heater element.
IMPORTANT: DO NOT TOUCH THE HEATER CUTOUT
BLADE.
Slide the heater terminals through the electric
end hanger bracket leaving the cutout assembly between
the heater and the backpanel.
Ensure that the elements are not crossed and the heater
end is supported on the bracket. Refit the washers then
nuts and tighten to secure.
11
Fit the grommet supplied on the heater assembly wires
into the slot on the hanger bracket, as shown in Fig. 5.
12
Fit the remaining No. 8 screw to the terminal end of the
relay. Locate the tab at the other end of the relay into the
slot behind the 7 way terminal and secure the relay with
the screw, (Fig. 5).
Fig. 5.
13
Refer to the wiring diagram below, and the one supplied on the unit side panel.
Connect the following wires:-
Orange (O)
-
to 7 way terminal block, terminal 7.
Blue (Bl)
-
to capacitor neutral piggyback.
Black (Bk)
-
to mains terminal, live.
Earth (G/Y)
-
to main earth terminal
Brown glasslap (B)
-
(shorter wire) to heater element.
Brown glasslap (B)
-
(longer wire) to relay terminal 14.
Blue wire (Bl)
-
from heater element to mains terminal, neutral.
(supplied loose)
Secure with the tie wraps supplied.
--o--o--O--O--O--o--o--
Heronhill - for all your Airking requirements
Tel: 01823 665660
www.heronhill.co.uk
Fax: 01823 665807