4 Installing the Lamp
The spotlight housing is supplied without
lamp. A PAR 36 lamp of 6 V/30 W max. with a
base with screw connection is required.
As a matching lamp, the halogen lamp HLT-
6/30 of the range “img Stage Line” is recom-
mended.
1) For easy installing of the lamp place the
spotlight housing so that it is supported
by the mounting bracket (3) [see figure].
For this purpose, slightly release the two
knob
screws (2), place the mounting
bracket into the desired position, and
tighten the knob screws again.
2) Turn off the screw cover (6).
3) For a lamp replacement remove the col -
our filter (5) in case it has been placed on
the lamp, and take the old lamp carefully
out of the housing. Release the two
screw connections which make the elec-
trical contact between the lamp base and
the connection cable of the lampholder.
Re move the old lamp.
4) Install the new lamp: slightly release the
two screws at the lamp base, tightly
clamp one cable lug each of the connec-
tion cable below each screw, and re
-
tighten the two screws. Carefully place
the lamp into the spotlight housing.
5) If a colour filter (5), e. g. LEF-36SET from
“img Stage Line”, is used, place same on
the lamp, and screw on the screw cover
(6) again.
5 Setting into Operation
1) Fix the unit via the mounting bracket (3)
with a support for light radiating units or a
stable mounting screw to the desired
place, e. g. to a cross arm for lighting
units or a stand.
2) For aligning the unit release the two knob
screws (2) at the mounting bracket, ad -
just the desired inclination of the unit, and
retighten the knob screws.
3) Connect the plug of the mains cable (1) to
a mains socket (230 V~/50 Hz). With con-
nection to the power supply the spotlight
is switched on.
4) For switching off the unit disconnect the
mains plug.
6 Specifications
Voltage supply: . . . 230 V~/50 Hz/40 VA
Lamp insert: . . . . . PAR 36 lamp
(6 V/30 W max.;
base: 2
×
screw)
Dimensions: . . . . .
∅
120 mm
×
160 mm
Weight: . . . . . . . . . 1.2 kg
Subject to technical modification.
The unit must be mounted in a safe and
expert way. If it is installed as a suspend-
ed load above persons, it must addition-
ally be secured (e. g. by a safety rope at
the mounting bracket; fix the safety rope
in such a way that the maximum falling
distance of the unit is 20 cm).
If the unit is to be put out of opera-
tion definitively, take it to a local
recycling plant for a disposal which
is not harmful to the environment.
WARNING
Prior to installing or removing
the lamp disconnect the mains
plug in any case!
G
As the lamp becomes very hot during
oper ation, at first let it cool down after
oper ation of the unit (cooling down time
at least 5 minutes) before replacing it.
G
Never use a lamp with a higher wattage
than 30 W.
7
GB
All rights reserved by MONACOR
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
may be reproduced in any form or by any means for any commercial use.