background image

 

3.GENERAL INFORMATION 

The following information and instructions within this manual may not cover all details or variations in the 
equipment, nor cover every problem that one may have during installation or use. If additional information 
is required please contact us

 

4. SAFETY INFORMATION 

The following procedures and instructions should always be carried out in order to prevent any injuries. 

If the machinery is not used as recommended, the operator will be responsible for his/her own safety and 
for the safety of the other persons who may be involved.   

The information in this manual aims to assist the operator to understand, maintain, and operate the 

mixer correctly. In order to prevent accidents, please ensure to read, understand and follow all the 
precautions and warnings contained in this manual before installation or operating. To gain a clear under 
straining of your mixer, it is imperative that one must study this manual carefully. 

Rotating machinery and Electricity are dangerous and may cause injury if sufficient precautions are not 

taken prior to operating or servicing the mixer. Ensure that the power supply is not connected to mixer and 
is isolated before starting work to clean or service the machine. In certain troubleshooting situations it may 
be necessary to operate the mixer; in which case extreme caution must be used. Only suitably qualified 
personnel must service the mixer. 

 

4.1 SAFETY GUIDELINES 
 

Ensure sufficient precautions are observed during manually handling of the mixer, particularly when 
moving the mixed into position on installation. Ensure to adhere to the manual handling regulations. 

 

This appliance is only for commercial and not for domestic use.   

 

The B series mixer is not intended for use by children. 

 

Whilst the machine is in operation, do not remove any covers or loosen any fittings. 

 

When mixing products that develop dust, extreme care must be taken. Mix the ingredients in speed 1 
until the dust is eliminated.   

 

Exposure to dust (including flour) may be harmful to health causing rhinitis (running nose), watering 
eyes and possibly occupational asthma.   

 

If dust is a hazard, ensure appropriate PPE (personal protective equipment) is used by operators, i.e., a 
mask.   

 

All operators must be trained in the safe operation of the mixer and attachments. 

 

This appliance is not to be used by anyone who with a lack of knowledge. Ensure all operators have 
been appropriately trained. 

 

This appliance is not intended to be used by those sensory, physical or mental capabilities prevent 
them from being able to operate it safely. 

 

Ensure the electrical supply has been isolated and the power cord disconnected before attempting to 
move or service the mixer.   

 

Be aware of the start capacitor situated behind the rear motor cover. In normal circumstances this 
should discharge when the mixer is switched off. If in doubt discharge the capacitor following adequate 
safety precautions.   

 

When accessing the electrical components inside the mixer, be cautious of exposed conductors that 
could be 'live'.   

 

Always  have  your  mixer  and  attachments  regularly  serviced;  at  least  twice  a  year,  depending  on 
frequency of use. 

 

Ensure this manual is kept in an easily accessible place for future reference near the mixer. 

 

Содержание B10

Страница 1: ...Planetary Mixer Instruction Manual Model B10 B20 B30 B40 B60 Please read this instruction manual carefully before operating this equipment ...

Страница 2: ... This appliance must only be used in accordance with these instructions and by persons competent to do so This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Keep all...

Страница 3: ...pose whether it be for flour mixing stuffing mixing and egg beating etc All the machine parts that come into contact with the food whilst in operation are made from stainless steel or their surfaces are specially treated in conformity with the Chinese hygiene standards Overall the machine is food looking easily operable and very efficient suitable for food preparation in hotels restaurants food pr...

Страница 4: ...er particularly when moving the mixed into position on installation Ensure to adhere to the manual handling regulations This appliance is only for commercial and not for domestic use The B series mixer is not intended for use by children Whilst the machine is in operation do not remove any covers or loosen any fittings When mixing products that develop dust extreme care must be taken Mix the ingre...

Страница 5: ...e gear lever to stop the machine Never Access rotating parts Never Use excessive force when operating which could affect the stability of the mixer Never Operate the mixer if parts are disassembled Never Fit the agitator to the mixer without a bowl in place Never Leave the agitator on the machine without the bowl being fitted Never Operate the mixer with both attachment and agitator fitted Never O...

Страница 6: ...e motor must be checked whether the machine rotates in the direction indicated by the rotation mark If the rotation direction is wrong exchange the two of the three livewires each other Note For test of machine mixing tools should never be installed otherwise they would fall out in case of wrong rotation direction and cause damage to machine parts 3 For every power educe line which has not attach ...

Страница 7: ...over 11 is fitted to the hub where applicable if an attachment is not in use Always remove any attachments before using the agitator Lower the bowl support by rotating the bowl handle downwards 3 Rotate the front guard cage assembly 10 to the open position Place the required agitator 9 into the bowl 7 and lift bowl onto the bowl support 5 Ensure that the rear bowl location 4 and side bowl pins 6 a...

Страница 8: ...h on Electric connectors are loose Check the electric circuit tighten those loose connectors Oil leakage Oil seals are worn out Replace those oil seals The raising handle is too tight Guide ways are corroded Clean and oil the guide ways The lead screw bevel gear and hand wheel shaft etc is dry Oil them Temperature rise of motor is too high below speed Lack of voltage Check the supply voltage Over ...

Страница 9: ...ring use Ensure that there is sufficient space around the mixer to allow for the safe operation Servicing may also become an issue if there is a greatly reduced clearance so ensure that the service accesses to the top side and rear of the mixer are clear 7 3 ELECTRICAL INSTALLATION The electrical installation of the mixer must conform to the local or national electricity board regulations A compet...

Страница 10: ...9 B30 B40 B60 ...

Страница 11: ...r into direct contact with food or with the hands of operators The best method of drying surfaces is to let them air dry but if this is not possible use paper towels or a clean dry cloth It is important the disinfecting chemicals are approved for food contact surface application 8 1 CLEANING BEFORE INITIAL USE Before using the mixer for the first time ensure to wash the mixer bowls agitators and a...

Страница 12: ...nsure that the bowl is in the down position Remove the bowl guard cage and agitator as described previously in section 8 3 1 Using a suitable bladed screwdriver remove the 3 retaining screws securing the drip cup to the mixer NOTE ensure that you have a firm grip on the shield whilst removing the screws The drip cup can be carefully lowered away from the machine Take care not to damage the paintwo...

Страница 13: ...s 1 24 Mixing shaft whip shaft 1 41 pole exist pole 1 8 Adjusting washer adjust gasket 1 25 espicyclic gear planet gear 1 42 Bowl pusher bowl press plank 1 9 jointer Zygosperm 1 26 Bowl support slide rack 1 43 base 1 10 Meshing gear joint gear 1 27 Bowl fix level bowl standing pin 2 44 Hand wheel handle 1 11 Main shaft washer gasket 1 28 fork dial fork 1 45 Link bar spring spring 1 12 Seal hose ai...

Страница 14: ...r small joint gear 1 29 fork dial fork 1 49 pole exist pole 1 10 Axel sleeve axis cover 1 30 Shift handle 1 50 Hand wheel handle 1 11 jointer Zygosperm 1 31 Shift handle base handle seat 1 51 pedestal press plank 2 12 Top cover 1 32 Electric sleeve Electricity cover 1 52 Link bar spring spring 1 13 Gear pusher cover 1 33 Front cover 1 53 Link bar connection haulm 1 14 Case cover bearing seat cover...

Страница 15: ...1 46 Bowl fix level Z201 2 9 Upper main shaft gear gearZ47 1 28 Ball bearing GCr15 1 47 base HT150 1 10 Bevel gear big cone gearZ 46 1 29 washer 65Mn 1 48 Bawl support HT150 1 11 Upper meshing gear joint gearZ 38 1 30 Pinion gear 40Cr 1 49 pedestal 45 2 12 Axel sleeve axis cover 1 31 Shift handle 45 1 50 Flexible casing 1 13 jointer 45 Zygosperm 1 32 Shift handle base 45 1 51 Fixed casing 1 14 bod...

Страница 16: ... 6 kg 9 kg 14 kg 21 kg Cake Pound 6 kg 10 kg 14 kg 18 kg Cake Short Sponge 3 kg 7 kg 11 kg 11 kg Cake Sponge 4 kg 6 kg 8 kg 19 kg Cookies Sugar 5 kg 7 kg 11 kg 14 kg Dough Bread or Roll Lt Med 60 AR 6 kg 11 kg 21 kg 21 kg Dough Heavy Bread 55 AR 4 kg 7 kg 14 kg 16 kg Dough Pie 5 kg 8 kg 12 kg 16 kg Dough Thin Pizza 40 AR max mix time 5 min 2 kg 4 kg 6 kg 11 kg Dough Med Pizza 50 AR 2 kg 5 kg 9 kg ...

Страница 17: ...ansferable This warranty is not assignable and applies only in favor the original purchaser user to whom delivered Any such assignment or transfer shall avoid the warranties herein made and shall avoid all warranties express or implied including any warranty of merchantability or fitness for a particular purpose Improperusage iMettos assumes no liability for parts or labor coverage for component f...

Страница 18: ...17 iMettos Limited www imettos co uk ...

Отзывы: