By entering PROGRAMS, you can change the default settings of a program by choosing the following functions:
-
Select the number of the program you want to change.
-
NAME: The name of the program will appear above its icon.
-
PROGRAM TYPE:
o
TIME = the program will last a time defined by the user.
o
AUTOMATIC = the program will last a variable time depending on the desired residual humidity
-
MULTISTEP (only if PROGRAM TYPE = TIMED): allows you to manage multiple drying steps, at different
temperatures, within the same program. For each step you can decide independently the temperature
and duration. The total duration of the program is the sum of all the durations of each step.
-
HEATING DURATION (only if PROGRAM TYPE = TIMED): It is the duration of the program defined by the
user.
-
HUMIDITY (only if PROGRAM TYPE = AUTOMATIC): Allows you to select three residual moisture values
among those already configured: IRON DRY (dry to iron) / DRY (dry to store) / EXTRA DRY (perfectly dry,
wearable / usable immediately).
-
CYCLE TEMPERATURE: It is the maximum temperature of the drying cycle
-
COOLING DURATION: At the end of the time defined in HEATING DURATION, a cooling cycle is conducted
(with the heating off), for which the maximum duration can be defined. Default = 3 min.
-
FINE COOLING TEMPERATURE: It is the temperature at which the cooling cycle must reach during its
execution. Default = 40°C. If this temperature is reached before the cooling DURATION expires, the cycle
will stop automatically.
-
ROTATION INVERSION (PRESENT /ABSENT): For machines equipped with basket inversion it is still
possible to exclude rotation in both directions. For machines not equipped with basket inversion this
parameter is always set to ABSENT.
-
FORWARD BASKET MOVEMENT TIME: clockwise rotation time.
-
BACK BASKET MOVEMENT TIME (only if ROTATION REVERSAL = PRESENT): counterclockwise rotation
time.
-
PAUSE BASKET MOVEMENT TIME (only if ROTATION REVERSAL = PRESENT): pause time between
hourly and counter clock locked rotation.
-
INITIAL COOLING: It is possible to set an initial cooling cycle with respect to the scheduled drying phase,
defining its duration. During this phase, the heating will remain off.
-
SPECIFIC PARAMETERS FOR SELF-SERVICE; the following parameters are visible only on machines
configured for a fee. An example of programming will be covered in a later chapter of this manual.
o
BASE TIME FOR SALE (only for self-service machines): It is the unit of time that is sold to the
customer when the machine is still in stand-by, i.e., before the selection and departure of the
program.
o
PRICE OF THE BASE TIME FOR SALE (only for self-service machines): It is the cost of the unit
of time defined above.
o
INCREASE TIME IN SALE (only for self-service machines): It is the unit of time that is sold to the
customer when the machine is already in operation. It is usually a fraction of the BASE TIME
defined above and corresponds to an increase in the total time of the program that the