E210501X rev.1_ENG
16/11/2021
13
TANDEM
MODEL
WASHING
MACHINE
HEATING
DRYER HEATING
VOLTAGE (V~)
[f=50/60 Hz]
CONSUMPTION
(A)
SUGGESTED
MINIMUM
CONDUCTOR
SECTION (mm
2
)
O11...
(TDM
11/11)
HOT WATER /
STEAM
ELECTRIC
3ph400V-480V (+N)
3ph230V
1ph230V
26
43
72
4
10
16
HOT WATER /
STEAM
GAS / STEAM
3ph400V-480V (+N)
3ph230V
1ph230V
5
6,5
9
2,5
2,5
2,5
ELECTRIC
ELECTRIC
3ph400V-480V (+N)
3ph230V
1ph230V
34
59
102
10
16
35
ELECTRIC
GAS / STEAM
3ph400V-480V (+N)
3ph230V
1ph230V
13
22,5
39
2,5
4
10
O88...
(TDM
18/18)
HOT WATER /
STEAM
ELECTRIC
3ph400V-480V (+N)
3ph230V
1ph230V
32
55,5
NOT
AVAILABLE.
6
16
NOT AVAILABLE.
HOT WATER /
STEAM
GAS / STEAM
3ph400V-480V (+N)
3ph230V
1ph230V
8
13,5
NOT
AVAILABLE.
2,5
2,5
NOT AVAILABLE.
ELECTRIC
ELECTRIC
3ph400V-480V (+N)
3ph230V
1ph230V
49
84
NOT
AVAILABLE.
6
25
NOT AVAILABLE.
ELECTRIC
GAS / STEAM
3ph400V-480V (+N)
3ph230V
1ph230V
25
42
NOT
AVAILABLE.
4
10
NOT AVAILABLE.
9. INSTALLATION: SPECIFICATIONS FOR GAS MACHINES
Any professional equipment with gas heating must be considered, regardless of the flow rate, a gas appliance.
During installation, the following requirements must be observed:
-
municipal and / or territorial building system and fire regulations
-
accident prevention regulations in force