E211101X_rev02_ENG
29/06/2022
27
MESSAGE / EFFECT
POSSIBLE CAUSE
Fabrics come out of ironing yellowed
Check if:
-
ironing temperature is too high and drying excessive
-
the ironing speed is too low, in reference to the
degree of residual moisture of the fabrics
-
there are residues of detergent, due to a poor rinsing:
the PH must be between 5 and 6
-
the fabrics are inserted over the entire length of the
ironing roller, and there are no roller zones at
different temperatures
-
call technical support
Fabrics come out of ironing with dark spots
Check if:
-
you used an ironing area greater than allowed, you
cannot iron outside the area delimited by the
introduction bands.
Fabrics come out of ironing deformed
Check if:
-
the introduction of fabrics is conducted correctly:
keep the fabric parallel to the hand-saving protection
-
call technical support
As soon as you press the START button, the machine
starts but stops immediately, and the display remains the
word "OFF"
Check if:
-
one of the "ENGINE THERMAL" or "GAS
PRESSURE" alarms intervened at a temperature
below 80 ° C
-
call technical support
The machine works normally, without alarms, but the
heating system does not start.
Check if:
-
the maximum temperature probe intervened: reset it
manually according to the procedure described.
-
if the machine is with gas heating, check that the
evacuation of the humid air is correct. If the
evacuation is not sufficient, the flame control unit
remains deactivated
-
call technical support
32.
REPORTS OF MALFUNCTION
If malfunctions, the microprocessor provides complete diagnostics. Below is the list of alarms. However, the user is
invited to contact, in these cases, an authorized service center for the solution of the problem occurred.
Please note that the activation of each of the following alarms is accompanied by the intermittent and continuous sound
of the buzzer.
-
OVERTEMPERATURE
The temperature of the roller has exceeded the safe limit. If this alarm occurs, the basin opens automatically, and the
suction is inserted (if any). The alarm is automatically removed when the temperature falls below full scale.
While the alarm is active, you cannot start the roller. Call Technical Support to verify the fault.
-
FAULT PROBE
There is a failure of the temperature probe, The behavior of the machine is the same as in case of overtemperature seen
previously. Call the Technical Support service.