Platinum™ Predator II-GX 2RU
Chapter 4
Installation and Operation Manual
Using ZConfigurator
© 2014 Imagine Communications.
Proprietary and Confidential.
Edition E | Page 66
Using the UMD and Tally LAN Interface
The default port used to communicate with an external 3rd party UMD and Tally controller over a LAN is
4003.
See also the port setup for Imagine Communications Routers that use the LRC protocol in UMD and Tally
Configuration (on page 61).
Using Serial Ports
For serial ports remember to select the Baud rate (default is 57600) and check the
Enable
box for Com 1
before using it. For RS485 (RS422) ports select a unique sub-address between 1 and 99 to allow multiple
ports to be identified.
A device can only be assigned to one port.
GPI Mapping
Each 4 input video card adds eight GPI input lines. Each of these GPI's can be individually configured for
Tally, Full screen Recall and Layout Recall as well as Timer start, pause and reset.
GPI lines can be assigned to control any function for any PiP. They are not tied to the video sources on
the video card where the physical connections happen to be fitted.