Chapter 2: Installation and Operation
Alarms
Table 2-6
lists the alarms that are displayed in CCS-enabled control
panels and software. The card-edge module
Status
LED also turns red
when one of these alarms is activated.
Table 2-6. CCS Alarms
Alarm Name
Severity
Meaning
Input Not Present
Major
The module does not detect an input signal.
Reclocker Not Locked
Major
The reclocker cannot lock to the input signal.
Unsupported Format
Minor
The input rate is not supported by the software key version.
Input Power Too High
Minor
The optical input power is too high. This alarm is generated
when the input power is greater than the following:
• 0 dBm (OP
+
OER
+
S)
• +3 dBm (OP
+
OER
+
SF
+
D)
• -9 dBm (OP
+
OER
+
HI
+
S)
• -6 dBm (OP
+
OER
+
SF
+
HI
+
D)