Rangehoods and overhead exhaust fans must be installed according to the ma-
nufacturers’ instructions and local regulations but in no case shall clearance from
hob burners be less than 650mm for the rangehood and 750mm for the overhead
exhaust fan. Any adjoining wall surface situated within 200mm from the edge of any
hob burner must be a suitable non-combustible material for a height of 330mm for
the entire length of the maintop. Any combustible construction above the hotplate
must be at least 780mm above the top of the burner and no construction shall be
within 450mm above the top of the burner. Zero clearance is permitted on the side
and rear adjoining surfaces below the maintop.
At all times gas safety regulations and local building codes must be adhered to.
The appliance must not be installed behind a decorative door in order to avoid
overheating.
The appliance can be installed as a freestanding cooker or on a plinth. If installing
the appliance as a freestanding cooker,
fi
t the telescopic legs to the appliance. If
installing the appliance on a plinth, then suitable ventilation from the plinth area is
required. It isrecommended that an air vent 20 mm wide and a length of 100mm
less than the width of the oven it is be located at the rear in the base of the plinth.
If the area under the plinth is sealed it is also recommended that an additional
vent be included at the top of kick panel under the plinth to provide adequate
circulation. The vent size should be 10mm high and 100mm less than the width of
the oven. Where installed on a plinth/base, measures must be taken to prevent the
appliance slipping from the base.
INSTRUCTIONS
FOR INSTALLATION
Installation of the cooker
Freestanding or Plinth
Installation
min. 750
min. 650
min. 50