ResMark 5000 High-Resolution
Section 2: Quick Start
400386 Operations Manual Rev A
Page 19
Step 11: Cap Unused Ports
After the installation is complete, it is recommended that all unused ports be capped to prevent accidental electrostatic discharge into
a connector.
Step 12: Create a Message and Control the Print System
Reference manual
Create & Control 400463
.
PHOTOSENSOR
ETHERNET TO
DOWNSTREAM
PRINT HEAD
OR HMI
24VDC
POWER
ENCODER
USB DEVICE OR
FIRMWARE UPGRADE
(HAS BUILT-IN CAP)
ETHERNET FROM
UPSTREAM PRINT HEAD
OR CUSTOMER NETWORK
The Primary print head should have all ports populated with a
cable.
Exceptions:
•
Only one head in the daisy chain - cap Ethernet and one
power port.
•
No encoder - cap encoder port.
•
Wireless communication - cap Ethernet ports.
•
No HMI - cap Ethernet port.
Secondary print heads will have most ports capped excluding
one power port.
Exceptions:
•
Wired Ethernet port - cap other Ethernet port.
•
Second power port is connected to HMI.
See “Service Parts and Optional Equipment” on page 47 for
plug and cap kits.