17
Basic installation and configuration
/Module configuration
F
For a connection without multiswitch, select the “0” value for the master module
inputs.
F
For a connection with multiswitch, select the value corresponding to the number of
multiswitch inputs. Next open the dropdown menu
lnb / mUltiSwitCh:
Ì
Satellite
: name of the input signal to the multiswitch for identification in
subsequent configurations: IKUSI recommends you identify the type of satellite,
polarity and the bandwidth of the signal.
Ì
mUltiSwitCh poSition:
notifies of the multiswitch input being described.
Ì
polarity (v):
click on the dropdown menu to select the polarity:
vertiCal
or
horizontal.
Ì
band (khz)
: for each polarity select
high
once and
low
once.
J
Save:
click on the button to save the changes.
Configuration of inputs
This permits the modification of the operating parameters for the master STC module
output. To enter from
headend > headend modUle liSt
, click on the magnifying
glass icon of the master module. Go to
SettingS >
inpUt
.
J
inpUt:
F
mUltiSwitCh oUtpUt:
click on the
dropdown menu to select one of the follow-
ing options:
Ì
For a connection with multiswitch select
the input for the multiswitch to be con-
nected to the STC.
Ì
For a connection without multiswitch
select
mUltiSwitCh off
.
F
fi band:
click on the dropdown menu to
select the intermediate satellite band type.
F
tranSponder freqUenCy (mhz):
permits the frequency value to be selected
for the transponder to be received.
F
freqUenCy fi (mhz):
permits the required intermediate frequency value to be
selected.
F
inpUt regime (kbit/s):
permits modification of the input speed value.
F
inpUt Signal:
shows if there is an input signal.
F
ber:
shows the rate for the bits that were incorrectly received by the input.
F
C/n (db):
shows the noise level in the input
signal.
F
Signal power:
shows the percentage power of the input signal with respect to
the maximum possible.
F
Save:
click on the button to save the changes.
EN