1.
When the F.VR control function selector switch is pressed up or down for
approx. 2 seconds together with pressing Knob Free, the mode for including
and deleting pages opens.
2.
In this setting mode, when the F.VR control function selector switch is
operated, the F.VR1 function is indicated at the upper section of the item
indicator, and F.VR2 function is indicated at the lower section of the item
indicator as a page information. Whether the corresponding page is included in
the sequence of page is also indicated at the camera number indicator.
3.
When the rotary switch is turned, selecting yes (Y) to include or no (N) to
delete becomes available.
4.
When the rotary switch is pressed, the selecting operation between yes (Y) and
no (N) is ended.
3.3 List of Pages for F.VR1 and F.VR2
Operation Page
Indicated Letters
Function
Page 1
RPED
F.VR 1: R Ped control
BPED
F.VR 2: B Ped control
Page 2
VCT
F.VR 1: VAR C.Temp control
MGAN
F.VR 2: Master Gain control
Page 3
MFLR
F.VR 1: Master Flare control
MGAN
F.VR 2: Master Gain control
Page 4
RFLR
F.VR 1: R Flare control
BFLR
F.VR 2: B Flare control
Page 5
GFLR
F.VR 1: G Flare control
MGAN
F.VR 2: Master Gain control
Page 6
RGAM
F.VR 1: R Gamma control
BGAM
F.VR 2: B Gamma control
Page 7
KNEP
F.VR 1: Knee Point Total control
KNES
F.VR 2: Knee Slope Total control
Page 8
SKIN
F.VR 1: Skin DTL Gain control
DTL
F.VR 2: DTL Gain control
Page 9
CSAT
F.VR 1: Color SAT. control
MGAM
F.VR 2: Master Gamma control
Содержание OCP-10
Страница 1: ...OCP 10 Operation Control Panel Operation Manual Products conforming to RoHS directive...
Страница 2: ......
Страница 10: ...SAFETY PRECAUTIONS...
Страница 12: ......
Страница 16: ......
Страница 18: ...2 1 3 External View 1 VR TYPE Option...
Страница 19: ...3 2 Slim TYPE...
Страница 20: ...4 3 JS TYPE Option...
Страница 59: ...43 10 Changing Information...
Страница 60: ......
Страница 62: ......