34
[Item setting mode]
It sets each of OCP and BS.
When a setting item is selected from the Ethernet
setting menu, the indication becomes as shown in the following drawing.
1
9
2
The boxes in the upper section indicate the image of IP address in four digits.
(Ex.: 192/168/1/100)
1.
Turning the rotary switch moves the black box in the upper section of the
character indicator.
2.
Select a digit to set (■ state) and press the rotary switch. The numeric value
in the lower section starts blinking. When the switch is turned in a blinking
state, the numeric value can be changed.
3.
After setting, press the rotary switch again. Turning operation of the rotary
switch returns to the box operation in the upper section.
4.
After setting all items, turn the rotary switch clockwise to the end while in
the upper section box operation state. The indication becomes as shown in the
following drawing.
S E T
5.
When the rotary switch is pressed while the screen in Step 4 is indicated, the
lower section starts blinking, and the indication changes between
"SET"/"CANC." When selecting SET, press the rotary switch with "SET."
The setting is saved.
* When "CANC" is selected, the screen returns to Ethernet setting menu
TOP.
When the OCP is set, the OCP restarts.
When the BS/CCU for connection is set, a change in connection
will occur.
Turn clockwise.
Turn clockwise
again.
1
6
8
1
Содержание OCP-10
Страница 1: ...OCP 10 Operation Control Panel Operation Manual Products conforming to RoHS directive...
Страница 2: ......
Страница 10: ...SAFETY PRECAUTIONS...
Страница 12: ......
Страница 16: ......
Страница 18: ...2 1 3 External View 1 VR TYPE Option...
Страница 19: ...3 2 Slim TYPE...
Страница 20: ...4 3 JS TYPE Option...
Страница 59: ...43 10 Changing Information...
Страница 60: ......
Страница 62: ......