27
7.2 List of Panel Configuration Settings
Item
Function
Set value
Remarks
IRIS CONT
Select
ABS (Absolute value
control)*1
Controlled with the absolute value
REL (Relative value
control)
Controlled with the relative value
GAIN RANGE
Select
6 dB *1
The control range is ± 6 dB.
3 dB
The control range is ± 3 dB.
FVR RANGE
Select
STD *1
The control range is the standard.
1/2
The control range is a half of the standard.
1/4
The control range is a quarter of the standard.
MPED RANGE
Select
STD *1
The control range is the standard.
1/2
The control range is a half of the standard.
1/4
The control range is a quarter of the standard.
VR DISP
VR value indication
ON *1
Indicates the volume control value on the character indicator.
OFF
Does not indicate the volume control value on the character indicator.
BUZZER
Select
STD *1
The buzzer volume is the standard.
ATT
The buzzer volume is a half of the standard.
OFF
The buzzer volume is mute.
TLY GARD
Select
OFF *1
The tally guard is off.
LIMT
The tally guard is set to the limited items.
ALL
The tally guard is set to all items.
MPED VALUE
Select
% *1
Indicates the video level.
CONT
Indicates the control data.
ADJUST MODE
IRIS position
adjustment function
-
Adjusts the IRIS position. *2
PROGRAM
MODE
Select
FIX *1
To be the FIX mode (OCP fixed) *3
CAM
To be the CAM mode (CAMERA prioritized) *3
OCP
To be the OCP mode (OCP prioritized) *3
PROGRAM No.
Select
OFF
Set a program number to be displayed on the camera number indicator.
PAU
Select
OFF *1
Not PAU operation
ON
To be PAU operation
EXT SEL 5-pin
Select
GTLY *1
Set the EXT connector (5-pin) output to the G TALLY output.
EXT
Set the EXT connector (5-pin) output to the EXTENDER output.
ALRM
Set the EXT connector (5-pin) output to the ALARM output.
EXT SEL 6-pin
Select
YTLY *1
Set the EXT connector (6-pin) output to the Y TALLY output.
EXT
Set the EXT connector (6-pin) output to the EXTENDER output.
ALRM
Set the EXT connector (6-pin) output to the ALARM output.
USER MODE
Select
COMP *1
No limit to the rotary switch select function/F. switch assign function. *4
BSIC
With limit to the rotary switch select function/F. switch assign function. *4
Ethernet
Ethernet setting
-
Set the IP address and other items. *5
RAM CLR
Select
MENU *1
Set the initialization of the customize item (other than Ethernet setting)
ALL
Set all initialization settings.
EXIT
End of the menu
mode
*1: Set the internal memory at the time of initialization.
*2: Refer to 7.4 IRIS Position Adjustment Function for details.
*3: Refer to 7.5 Program Number Indication for details.
*4: Refer to 7.6 Use Limit Function by User for details.
*5: Refer to 7.7 IP Address/Subnet Mask/Default Gateway Setting for details.
Содержание OCP-10
Страница 1: ...OCP 10 Operation Control Panel Operation Manual Products conforming to RoHS directive...
Страница 2: ......
Страница 10: ...SAFETY PRECAUTIONS...
Страница 12: ......
Страница 16: ......
Страница 18: ...2 1 3 External View 1 VR TYPE Option...
Страница 19: ...3 2 Slim TYPE...
Страница 20: ...4 3 JS TYPE Option...
Страница 59: ...43 10 Changing Information...
Страница 60: ......
Страница 62: ......