5.1.2 Setting
Measure the SYNC output waveforms of the CCU master and slave and adjust the PHASE so
that the H/V phases match. When adjusting, adjust the slave side (side on which the
GENLOCK connector is connected). Phase adjustment is not required on the Master side.
5.2. Manual Setting a Metering Frame
You can change the range of a metering frame as desired. By adjusting a metering frame, a
video can automatically be adjusted in keeping with the use environment.
5.2.1 Setting
Select
>$(0RGH@ĺ>$UHD6HOHFW@ĺ>86(5@IURPWKHPHQX
and press the SET button.
The
system goes to the manual setting screen for a metering frame
.
Possible to set the position and size of the
metering frame.
:KHQVHWWLQJLV¿QLVKHG
, select QUIT
DQGSUHVVWKH6(7EXWWRQWR¿QLVKVHWWLQJ