1.2. Front Panel of Camera Control Unit (CCU) 

MKC-210HD

POWER

AWB

GAIN

PAINT/AE

FUNCTION/SET

BARS

FREEZ

SCENE

MENU

1

3

2

4

1

  POWER button

2

  AWB button

3

  GAIN button

4

  PAINT/AE button

5

  BARS button

6

  FREEZ button

7

  SCENE button

10

  MENU button

8

  Arrow keys

9

  FUNCTION/SET button

 

1

 POWER  button

  This is the power button of the MKC-210HD.

2

 AWB  button

  To execute Auto White Balance. (See page 12

3

 GAIN  button

  Automatic gain control to insure that the output level of the image signal is always constant in relation to the 

brightness of the photographic image. If this function is used effectively, the GAIN button remains lit green. (See 
page 15)

4

 PAINT/AE  button

  Possible to adjust the AE level and the intensity of red and blue of the image. (See pages 13, 14)

5

 BARS  button

  Output an internal color bar signal of the camera to a color monitor. Can be used to adjust the color monitor 

brightness, contrast, etc. (See page 16)

6

 FREEZ  button

  Possible to freeze the screen image. (See page 15)

7

 SCENE  button

  Used when selecting a scene fi le. (See page 17)

8

 Arrow  keys

  Used to select scene fi les or operate the menu.

9

 FUNCTION/SET  button

  Press to determine the item you wish to set with the menu displayed. Refer to “Menu Operation”.

10

 MENU button

  To display the menu that the user can set as desired on the monitor.
  Select an item you want to set with 

8

  Arrow key and defi ne it with 

9

  Menu Switch for menu items you can 

set.

  Refer to “Menu Operation” (Page 18) for further detailed operations.

Содержание MKC-210HD

Страница 1: ...MKC 210HD Digital Process Compact FULL HDTV Color Camera Operation Manual MKC 210HD MKC 210HD POWER AWB GAIN PAINT AE FUNCTION SET BARS FREEZ SCENE MENU 1 3 2 4...

Страница 2: ...The copyright of the software made for this product is in Ikegami Tsushinki Co Ltd It forbids to reproduction a change and so on about a part of this calligraphy or all without notice...

Страница 3: ...a metal body or ammable material into the opening of the unit Do not drop in such material A re or electric shock may be caused Do not make alterations to the unit A re or electric shock may be caused...

Страница 4: ...sing an physical damage to the waist or hand or a physical injury Take preventive measures against the overturn of the unit due to an earthquake or sudden shock As the unit may overturn and cause a ph...

Страница 5: ...3 6V m unmodulated r m s 1kHz AM 80 Complied Electrical fast transient burst IEC61000 4 4 AC power ports 2kV 5 50ns 2kV 5 50ns 5kHz and 100kHz Complied Signal ports 1kV 5 50ns 1kV 5 50ns 5kHz and 100...

Страница 6: ...3 Menu Operation 18 3 1 Operation Method 18 3 2 Video Adjust 19 3 3 AE Mode 20 3 4 Detail 22 3 5 Video Setting 23 3 6 Picture Setting 24 3 7 Scene File 25 3 8 Foot Switch 26 3 9 White Balance 27 3 10...

Страница 7: ...s optional substrate 35 4 4 1 SD Card Recording 35 4 4 2 For cards on which recording is nished 35 5 Speci cation 36 5 1 Ratings 36 5 2 Performance 36 5 3 Functions 37 6 External Appearance 38 6 1 Cam...

Страница 8: ...era head side and CCU side 3 Flange focus adjustment ring Flange focus distance from the lens mounting surface to the photographed surface adjustment ring Adjust the ange focus to use the lens focus f...

Страница 9: ...page 15 4 PAINT AE button Possible to adjust the AE level and the intensity of red and blue of the image See pages 13 14 5 BARS button Output an internal color bar signal of the camera to a color moni...

Страница 10: ...ble extension from the foot switch 5 IRIS Connector Connects the IRIS cable of a special microscope adapter 6 Camera Connector Connects with camera connector of the special camera cable Be aware that...

Страница 11: ...igher 15 SD CARD This is the insertion port for the SD card The SD card is not included in the equipment spec Note Please note we assume no responsibility for warranty when videos are not saved due to...

Страница 12: ...D CCU HD SDI compatible Coaxial cable Terminate the output from VIDEO OUT at 75ohms on the receiver side For connection of the power supply be sure to use the accessory AC adapter Caution at connectio...

Страница 13: ...the state of still screen picture that state will not be held even if power is turned on again and MKC 210HD is set to the normal shooting state When moving the CCU be sure to turn off the POWER disco...

Страница 14: ...tic adjustment the AWB button is lit green MKC 210HD POWER AWB GAIN PAINT AE FUNCTION SET BARS FREEZ SCENE MENU 1 3 2 4 AWB button If AWB is displayed on the monitor screen and it ends normally AWB CO...

Страница 15: ...een If the button is already lit it is not necessary to push it MKC 210HD POWER AWB GAIN PAINT AE FUNCTION SET BARS FREEZ SCENE MENU 1 3 2 4 PAINT AE button Lit 2 Use the arrow keys to adjust the red...

Страница 16: ...tion 1 Con rm that the PAINT AE button is not lit If it is lit press the PAINT AE button to extinguish it MKC 210HD POWER AWB GAIN PAINT AE FUNCTION SET BARS FREEZ SCENE MENU 1 3 2 4 PAINT AE button E...

Страница 17: ...OWER AWB GAIN PAINT AE FUNCTION SET BARS FREEZ SCENE MENU 1 3 2 4 GAIN button 2 To stop automatic gain adjustment press the GAIN button again The GAIN button extinguishes White spots may appear on the...

Страница 18: ...r brightness contrast etc Operation 1 Press BARS button Immediately changes to color bar output During color bar output the BARS button is lit green MKC 210HD POWER AWB GAIN PAINT AE FUNCTION SET BARS...

Страница 19: ...arrow key is lit that corresponds to the presently selected scene le MKC 210HD POWER AWB GAIN PAINT AE FUNCTION SET BARS FREEZ SCENE MENU 1 3 2 4 SCENE button 2 Use the arrow keys to select the scene...

Страница 20: ...Switch White Balance IP ENC Setting 1 Miscellaneous Version Information 1 The IP ENC item is only displayed if the optional substrate is mounted 2 Use the keys on the front of the CCU to select the i...

Страница 21: ...deo Level Adjusts the image signal level Normally not used 64 to 63 Increasing the value produces a bright image Decreasing the value produces a dark image Gain Offset Red Adjusts the red level This i...

Страница 22: ...rried out in the item entitled Manual Shutter Manual Shutter The shutter speed when the shutter control is in FIX is set here If set to AUTO it is ignored It is usually used in the OFF setting OFF The...

Страница 23: ...r is the photometry area FULL The entire screen is the photometry area USER Allows arbitrary setting of the photometry area Press the SET button to enter the setting screen For details on settings see...

Страница 24: ...image is clearer and easier to view Set it to ON usually ON Carries out contour enhancement OFF Does not carry out contour enhancement Detail Gain To adjust the detail enhancement level 128 to 127 Inc...

Страница 25: ...ed the dark sections of the image to be displayed brightly Normally this is used in an ON setting ON Carries out gamma correction OFF Does not carry out gamma correction Master Gamma Adjusts the degre...

Страница 26: ...f a moving photographic subject H Flip Sets the horizontal inversion of the image ON Inverts to a horizontal direction for output OFF The horizontal direction becomes the normal rotation output V Flip...

Страница 27: ...le Quit Scene Number No 1 Store Scene READY Initialize Scene READY Item Setting Value Description Scene Number Select and read the set scene le Store Scene Store the set condition in the scene le Sele...

Страница 28: ...ed out even when the foot switch is operated FREEZE Outputs still images Operate the foot switch again to return to moving images SCENE FILE Switches the scene le selection H FLIP Outputs a horizontal...

Страница 29: ...n AWB The white balance is adjusted automatically Press the SET button when this item is selected MANUAL Manual adjustment of white balance Adjustment is carried out with Manual Gain Red Blue Manual G...

Страница 30: ...method SNAPSHOT Compress with JPEG method and record on the SD card STREAMING Compress with the H 264 method and distribute the image JPEG Quality Sets the image quality if the compression method is s...

Страница 31: ...nection with the network To protect the system from harm specific to the network connection please conduct sufficient security measures under your own responsibility Network specific harm includes lea...

Страница 32: ...enu Lock Menu lock ON Sets a state in which no settings other than Menu Lock can be changed During Menu Lock a red lock mark is displayed in the upper right of the menu screen OFF Sets to a state in w...

Страница 33: ...on Information To display the software version of this camera Version Information Quit Model MKC 210HD CCU Firmware V1 00 CCU FPGA V1 00 Head FPGA V1 00 IP ENC 1 V1 00 1 Only displayed if IP ENC modul...

Страница 34: ...tion 3 value SYNC 0 6 Vp p 75 Ohms 4 1 1 Wiring connection example Prepare two sets of CCU and camera for the MKC 210HD Connect the SYNC connector of CCU Master and the GENLOCK connector of CCU Slave...

Страница 35: ...nual setting of photometry frame The Photometry frame can be changed within a random range By adjusting the photometry frame automatic adjustment of the image to match the usage environment is possibl...

Страница 36: ...hen adjustment is nished press the SET button to complete adjustment Size Setting Select Size and press the SET button to adjust the size of the photometry frame The upper left corner of the frame is...

Страница 37: ...cted scene le is immediately initialized 4 3 3 Setting of Scene File To use the stored scene le operate the front panel See page 17 or the foot switch See page 26 or the menu Scene File See page 25 4...

Страница 38: ...ohms C 0 286Vp p 75 ohms 7 Camera Cable 5m Standard option Round connectors 20 pins 8 Auto Iris DC Iris Round connectors 4 pins 9 Input Control Signal RS 232C 1 Line D Sub 9pin Male FOOT SW 1 Line D...

Страница 39: ...r IRIS DC IRIS 5 Photometry area variation function 6 Character display function English German French Spanish 7 Internal freeze function 8 Internal color bar 9 Image tilt function left right up down...

Страница 40: ...nit mm MKC 210HD 14 31 2 31 2 15 5 0 5 36 2 6 2 M3 14 6 2 M3 6 2 CCU Unit mm RS 232C VBS Y C DVI FOOT SW SYNC POWER GENLOCK 1 2 HD SDI IRIS CAMERA MKC 210HD POWER AWB GAIN PAINT AE FUNCTION SET BARS F...

Страница 41: ...egami Tsushinki Co Ltd All right reserved Production or duplication without permission of IKEGAMI Tsushinki Co Ltd of editorial or pictorial content in whole or in part in any manner is prohibited Spe...

Страница 42: ...146 Japan Phone 03 5700 1111 Fax 03 5700 1137 Ikegami Electronics U S A Inc 37 Brook Avenue Maywood New Jersey 07607 U S A Phone 201 368 9171 Fax 201 569 1626 Ikegami Electronics Europe GmbH Ikegami s...