18
SHUTTER
If the electronic sensitivity increase mode is OFF (SENS UP =
OFF), it is possible to select the high-speed shutter.
If set to FL, flicker (resulting from fluorescent lamps, etc.) is
eliminated.
If the electronic sensitivity mode is ON (SENS UP = ON), it is
possible to set the magnification for electronic sensitivity UP.
LIGHT CONT. If the [E] button is pressed, the submenu LIGHT CONTROL is
displayed, and it is possible to adjust the auto-iris lens aperture
and the backlight compensation (Note 1).
For details, See Section 6-2-3.
GAIN
Possible to set image brightness.
LOW
Fixed sensitivity for bright locations.
MID
Fixed sensitivity between LOW and HIGH.
HIGH
Fixed setting for dark locations.
AGC
Standard automatic sensitivity adjustment.
HYP-AGC High-sensitivity automatic sensitivity adjustment.
WHITE BAL.
For adjusting difference in color tone due to light source
differences (white balance).
ATW1
Automatic tracking toward light source (Note 2).
ATW2
Used when the color temperature adjustment range
is wider than ATW1 and with a sodium lighting.
AWC
Automatic adjustment
Focus on the white object that is the target and
press the [E] button.
Before adjustment: AWC PUSH is displayed.
During adjustment: AWC - - - -
is displayed.
When adjustment is finished:
AWC SET
is displayed.
Following that:
AWC PUSH is displayed.
If AWC NG is displayed, see Note 3.
MANUAL Press the [E] button to display the WHITE
BALANCE submenu and carry out manual
adjustment.
For details, See Section 6-2-4.