13
Step 1: Create a lower hole on the installation site for the M4 attachment screws.
When necessary, create wiring holes (diameter: 50-60 mm).
Step 2: Following the steps in Section 5-1 (Removing the dome cover), remove
the dome cover from the camera main unit.
Step 3: Attach the accessory attachment fixtures with the M4 screws. Also
secure at this time together with the M4 screws the anti-drop wire in the
position shown in the figure. The direction of the
△
mark appearing on
the attachment fixture should be the front when attaching the camera.
Step 4: Attach the anti-drop wire with a screw to the camera main unit side.
Step 5: Insert section A on the attachment fixture in holes A’ (2 locations) on the
camera main unit and turn the camera unit as far as possible in a
counterclockwise direction.
Step 6: Use a screwdriver to tighten the retention screws on the camera main
unit interior and attach the camera to the retention fixture.
Step 7: After lens adjustment and user setup, attach the dome cover in the
order shown in Section 5-2 (Attaching the dome cover).
Notes
1 ) After installation, turn the dome cover in a clockwise direction
and confirm that it is securely attached.
2 ) When attaching the cable, remove section B when necessary for
use.