background image

5

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Level

Drill with 1¼" (3.0 cm), 

³⁄₈

" (9.5 mm), 

⁷⁄₆₄

" (2.75 mm) and 

¹⁄₈

" (3.0 mm) drill bits

Pencil

Wire stripper or utility knife

Tape measure or ruler

Pliers

Caulking gun and weatherproof caulking compound

Vent clamps

Jigsaw or keyhole saw

Flat-blade screwdriver

Metal snips

Phillips screwdriver

Parts needed

Home power supply cable

Two ½" (12.7 mm) UL listed or CSA approved strain reliefs

3 UL listed wire connectors

For vented installations, you will also need:

1 wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also 
need:

Charcoal Filter Kit Part Number 4396848 for non-vented 
(recirculating) installations only. See “Assistance or Service” 
section to order.

Parts supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator, light bulb and grease 
filter installed

Front panel

Deflector for non-vented (recirculating) installations

Transition with back draft dampers installed

Literature package

2 mounting hooks with leveling screws

Vent cover support bracket (3 pieces, to assemble)

Mounting template

2-piece vent cover

4 - 4 x 8 mm screws

10 - 3.5 x 9.5 mm screws

6 - 5 x 35 mm screws

2 - 2.9 x 9.5 mm screws

2 - 6 x 70 mm screws

2 - 10 mm wall plugs

4 washers

2 screwdriver bits for TORX

®†

 screws

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial rating 
plate is located behind the left filter on the rear wall of the vent 
hood.

Range hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents. 

Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical 
Requirements” section.

The range hood is factory set for venting through the roof or wall. 
For non-vented (recirculating) Installation see “Non-vented 
(recirculating) Installations” in “Prepare Location” section. 
Charcoal Filter Kit Part Number 4396848 is available from your 
dealer or an authorized parts distributor. 

All openings in ceiling and wall where range hood will be installed 
must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local 
codes.

Product Dimensions

†®TORX is a registered trademark of Acument Intellectual Properties, LLC.

(28.4 cm)

(27.3 cm)

(8.0 cm)

(3.5 cm)

(10.0 cm)

135

o

11.2"

10.7"

31.9" (81 cm) min

35.4" (90 cm) min
(non-vented
recirculating
installation)

46.5" (118 cm) 
max

3.1"

1.4"

3.9"

24" (61.0 cm) - 30" (76.2 cm)

       14.2"
(36.0 cm)

       16.7"
(42.4 cm)

Содержание W10177447B

Страница 1: ...DE CUISINI RE POUR MONTAGE MURAL 24 61 cm 30 76 2 cm Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composez le 1 866 664 2449 Tab...

Страница 2: ...In Canada 15 Accessories 15 WARRANTY 16 TABLE DES MATI RES S CURIT DE LA HOTTE DE CUISINI RE 17 EXIGENCES D INSTALLATION 19 Outillage et pi ces 19 Exigences d emplacement 19 Exigences concernant l va...

Страница 3: ...instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all saf...

Страница 4: ...nd to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY M...

Страница 5: ...codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model...

Страница 6: ...rs the heated portion of the house Makeup air Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement The specified CFM...

Страница 7: ...as aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors a...

Страница 8: ...nted and non vented recirculating installations 7 Tape template in place aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall 8 Mark...

Страница 9: ...make the connection in the hood s electrical terminal box 4 Use caulk to seal all openings NOTE Do not reconnect power until installation is complete InstallRangeHood 1 Using 2 or more people hang ran...

Страница 10: ...D together 6 Use UL listed wire connectors and connect white wires F together 7 Connect green or bare ground wire from home power supply to yellow green ground wire E in terminal box using UL listed...

Страница 11: ...ith the lock springs on the front panel 6 Press the front panel firmly into place 7 Check to ensure that the front panel is locked into place CheckOperation 1 Press the A button to turn the light on o...

Страница 12: ...before cleaning the hood Exterior Surfaces Clean the range hood with a mild detergent and soft cloth To avoid damage to the exterior surface do not use abrasive cleanser or steel wool pads Metal Grea...

Страница 13: ...pushing handle toward the rear and pull downward 4 Pull filter toward front and set aside 5 Turn charcoal filter counterclockwise 6 Remove and discard charcoal filter 7 Repeat to remove other charcoal...

Страница 14: ...14 WIRING DIAGRAM...

Страница 15: ...chnicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the Whirlpool designated service company in your area you can also look...

Страница 16: ...ng codes or use of consumables or cleaning products not approved for use Cosmetic damage including scratches dents chips or other damage to the finish of your major appliance unless such damage result...

Страница 17: ...t de blessures graves vous et d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient Keep this book and your sales slip tog...

Страница 18: ...jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR R DUIRE LE RISQUE D INCEND...

Страница 19: ...ort du cache conduit 3 pi ces assembler Gabarit de montage avec pieds de nivellement Cache conduit 2 pi ces 4 vis de 4 x 8 mm 10 vis de 3 5 x 9 5 mm 6 vis de 5 x 35 mm 2 vis de 2 9 x 9 5 mm 2 vis de 6...

Страница 20: ...r un fonctionnement efficace et silencieux Ne pas utiliser plus de trois coudes 90 Veiller ce qu il y ait une section droite de conduit de 24 61 0 cm ou plus entre deux coudes si on doit utiliser plus...

Страница 21: ...t causer une r tro pression et des turbulences de l air ce qui r duit consid rablement la performance La sortie l ext rieur du circuit d vacuation peut se faire travers le toit ou travers un mur Pour...

Страница 22: ...re dition et de tous les codes et r glements en vigueur INSTRUCTIONS D INSTALLATION Pr parationdel emplacement On recommande que le circuit d vacuation soit install avant l installation de la hotte Av...

Страница 23: ...Code national de l lectricit normes CSA ou codes r glements locaux il faut que la longueur du conduit de et des conducteurs soit suffisante depuis le tableau de distribution avec fusibles ou disjonct...

Страница 24: ...u d flecteur 3 Installer le conduit d air entre le raccord de transition et le d flecteur 4 Utiliser des brides de serrage pour sceller chaque connexion 5 Enlever le filtre graisse Raccordement lectri...

Страница 25: ...onnecter la source de courant lectrique Acheverl installation 1 Installer le cache conduit Pousser la section inf rieure du cache conduit vers le bas sur la hotte et soulever la section sup rieure du...

Страница 26: ...le est grill 5 D connecter la source de courant lectrique 6 V rifier que le c blage est correct 7 Replacer pi ces et panneaux avant de faire la remise en marche 8 Reconnecter la source de courant lect...

Страница 27: ...ltre dans la rainure arri re de l ouverture d installation du filtre 2 Pousser la manette vers l arri re et pousser le filtre vers le haut 3 Tirer le filtre vers l avant pour l ins rer dans la rainure...

Страница 28: ...dans Installation des filtres charbon et faire pivoter le filtre dans le sens horaire pour le verrouillage 9 R p ter l tape 9 pour installer l autre filtre charbon Remplacement d une lampe halog ne I...

Страница 29: ...GRIS BL R N BU BU R BL MAR JA N L N BL JA VE N BL N INTERFACE UTILISATEUR BU R BL N VITESSE K1 K2 K3 K4 1 MARCHE 2 ARR T 3 4 MOTEUR NIVEAU K5 K6 LUMI RE MAX MARCHE MOYEN ARR T 1 1 NOIR BLEU VERT MARRO...

Страница 30: ...AuCanada Veuillez appeler sans frais le Centre pour l eXp rience de la client le de Whirlpool Canada LP au 1 866 664 2449 Nos consultants vous renseigneront sur les sujets suivants Caract ristiques e...

Страница 31: ...s de nettoyage dont l utilisation n est pas approuv e Les d fauts d apparence notamment les raflures traces de choc fissures ou tout autre dommage subi par le fini du gros appareil m nager moins que c...

Страница 32: ...sur la plaque signal tique situ e sur le produit Nom du marchand ______________________________________________ Adresse ________________________________________________________ Num ro de t l phone ___...

Отзывы: