background image

www.ikancorp.com | 1.713.272.8822 | [email protected] 

because we’re 

filmmakers

 too

Periodic Fixture Inspection

1.  The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours or at least once a year. This 

frequency may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar 
spare parts. 

2.  The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise 

explosion might occur. Defer to instructions provided by the lamp manufacturer.  

3.  Always check the safety shield before every use. 

4.  All high-voltage components (ex: voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a 

year. 

5.  Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield. This will allow 

inspections of accessories and the holding clamps. 

6.  The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or 

broken. It is essential for the performance of the fixture.

Specifications & Photometrics

LSC-004 Specifications

Beam Angle

7° to 60°

Build Material

Aluminum

Color Temperature

5600K

Cooling System

Air Cooled

Fixture Size

29 x 20.3 x 15.6 in.

Fixture Weight

43 lbs

Focusing

Knob Control

Head Type

HMI Fresnel 2500W

IP Class

IP23

Lamp Base

2500W / 115V / G38

Lens Size

Fresnel 9.8"

Yoke

Cast Aluminum with 1 1/8" Pin

LUX

METERS

9M

12M

15M

18520

10410

6670

LUX

METERS

9M

12M

15M

1545

870

550

FC

FEET

29.5'

39'

49'

1720.5

967.1

619.7

FC

FEET

29.5'

39'

49'

143.5

80.8

51.1

Отзывы: