SMRA - SSI and BiSS
WARNING
Please be sure that the mounting tolerances indicated in Figure 3 are always
met. Avoid contact between the parts.
Figure 3
WARNING
Mount the sensor as shown in the Figures. Please mind the direction of the
cable outlet. The system cannot operate if mounted otherwise than illustrated in
the Figures.
WARNING
The arrow in Figure 1 is intended to indicate the
standard counting direction
(count up information when the ring turns in the direction of the arrow). See
also the “4.6 Counting direction input” section on page 17.
WARNING
After having installed the sensor on the magnetic ring a zero/preset setting
operation is compulsorily required. The zero/preset setting operation is further
required every time either the sensor or the ring are replaced. For any
information on the zero/preset setting operation please refer to the “4.5 Zero
setting/Preset input” section on page 16 and (BiSS interface only) to the
registers on page 27.