SMRA - SSI and BiSS
4 – Electrical connections
WARNING
Electrical connection must be carried out by qualified personnel only, with
power supply disconnected and mechanical parts compulsorily in stop.
WARNING
If wires of unused signals come in contact, irreparable damage could be caused
to the device. Please insulate them singularly.
Function
M8 cable
M12 8-pin
0Vdc power supply
Black
1
+Vdc power supply *
Red
2
Clock IN + / MA +
Yellow
3
Clock IN - / MA -
Blue
4
Data OUT + / SLO +
Green
5
Data OUT - / SLO -
Orange
6
Zero setting/Preset
White
7
Counting direction
Grey
8
Shielding
Shield
Case
* See the order code for power supply voltage level
EXAMPLE
SMRA-GG
1
-14
+Vdc = +5Vdc ± 5%
SMRA-GG
2
-14
+Vdc = +10Vdc +30Vdc
4.1 M8 cable specifications
Model
: LIKA HI-FLEX sensor cable type M8
Wires
: 2 x 0.22 mm
2
+ 6 x 0.14 mm
2
(24/26 AWG)
Jacket
: Matt Polyurethane (TPU) halogen free, oil, hydrolysis,
abrasion resistant
Shield
: tinned copper braid, coverage
85%
Outer diameter
: 5.3 mm ÷ 5.6 mm (0.209” ÷ 0.220”)
Min. bend radius
: Ø x 7.5
Work temperature
: -40°C +90°C (-40°F +194°F) – dynamic installation
-50°C +90°C (-58°F +194°F) – fixed installation
Conductor resistance :
90
/km /
148
/km
MAN SMRA SSI_BiSS E 1.4.odt