Cause
Troubleshooting
•
Supply line or mixing chamber
clogged up
Remove deposits in the
machine and/or pipework
•
trapped air in the mixing
chamber or suction pipe, par-
ticularly in case of horizontal
suction pipe
Vent device and/or suc-
tion pipe
•
Wrong direction of rotation
Change 2 phases of the
current supply
•
too low speed
Increase the speed
•
•
wear of the interior parts
Replace worn parts
•
unsufficient torque at the shrink
disc
Tighten all screws acc. to
documentation