Specifications
2021-07-07
57
7.1.5 RJ45 (Interconnect)
Communication between Cat X devices requires a 1000BASE-T
connection.
Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with
RJ45 connectors at both ends. All four cable wire pairs are used.
Pos: 72 /806-IHSE/T echnische D aten/Schnittstell en/Gl asfaser SF P Typ LC @ 5\m od_1278937700855_6.doc @ 43149 @ 3 @ 1
7.1.6 Fiber SFP Type LC (Interconnect)
Communication of fiber devices is performed via Gigabit SFPs that are
connected to suitable fibers fitted with connectors type LC (see Chapter
7.2.2, Page 62).
The correct function of the device can only be guaranteed with SFPs
provided by the manufacturer.
SFP modules can be damaged by electrostatic discharge (ESD).
Please consider ESD handling specifications.
Pos: 73 /806-IHSE/T echnische D aten/Schnittstell en/Seriell e Schnittstell e @ 5\mod_1291127444390_6.doc @ 44828 @ 3 @ 1
7.1.7 Serial Interface
The serial interface option supports a
full-duplex transmission
with a real
hardware handshake up to a Baud rate of 115,200 Baud.
The CON Unit is cabled as DTE (Data Terminal Equipment, like CPU
output) and can be connected directly to DCE devices (Data
Communication Equipment).
A touch screen can be connected directly to the CON Unit.
To connect to a serial printer (or any other DTE instead of DCE
device), you need a null modem cable (crossed cable) between CON
Unit and the device.
Operation of several devices:
The serial interface transmits 6 signals (3 for each direction).
Normally,
4 of the 6 signals are handshake signals (in addition to RxD and TxD).
The following configurations, however, can be realized using special
adapter splitting cables:
Three single 2-wire transmissions
Two transmissions with a handshake signal
A serial mouse and a single 2-wire transmission.