background image

SuperiorFireplaces.us.com

900463-01E

19

INSTALLATION

Continued

 

and 25B. Figure 25A

 shows how the log must 

fi t against the end of the burner. 

Figure 25B

 

shows  how  the  notch  in  log  fi ts  against  the 
vertical portion of the burner tube. Place this 
log on the base assembly by inserting it from 
the left side as shown in 

Figure 25

. You will 

need  to  twist  the  log  slightly  to  get  it  to  fi t 
against the burners properly. It will rest even 
with the back edge of the pan.

3.  Find  the  front  left  log  (LMF24GTA/B  or 

LMF24MOA/B models: D-059, LMF30GTA/B or  
LMF30MOA/B models:  D-017, LMF36GTA/B or 
LMF36MOA/B models: D-025). See 

Figures 26, 

26A, 

Figure 24C - Installing Right Front Log, Side 

View

Figure 25 - Installing Back Left Log

Back Left Log (D-060, 
D-018 or D026)

Flat Part of Log

Log Notch

Burner Tube

Figure 25A - Installing Back Left Log

Figure 25B - Installing Back Left Log 

(D-018) Rear View

Burner 
Tube

Log 
Notch

Vertical Portion of Burner Tube

 

and 26B

. The log has a rectangular stand off 

on the bottom that fi ts against the lip on the 
black metal base as shown in 

Figure

 

26A

. The 

bottom of this log has a slot that fi ts over the 
second bar on the grate as shown in 

Figure 

26B, Page 20

. Place the log on the base as-

sembly as shown in fi gures.

4.  Find the charred log (D-020). See 

Figures 27, 

27A, and 27B

. The log has a slot in the bottom 

that fi ts over the square grate and rests against 
the burner tube as shown in 

Figure 26 - Installing Front Left Log

Front Left Log (D-059, 
D-017 or D025)

Figure 26A - Installing Front Left Log Side View

Grate Fingers

Содержание Superior Fireplaces MNF24INM

Страница 1: ...NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs This is an unvented gas fired heater It...

Страница 2: ...G This appliance is for installation only in a solid fuel burning masonry or UL127 factory built fireplace or in a listed ventless firebox enclosure It is design certified for these installations in a...

Страница 3: ...to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Heater will remain hot for a time after shutdown Allow surface to cool before touching Young childre...

Страница 4: ...ventilation to run properly This appliance has an Oxygen Depletion Sensing ODS safety shutoff system TheODSshutsdowntheapplianceifenoughfresh air is not available See Air for Combustion and Ventilati...

Страница 5: ...on Inc 1 Batterymarch Park Quincy MA 02169 7471 UNPACKING 1 Remove log set assembly from carton CAUTION Donotremovethedata plates from the grate assembly The data plates contain important war ranty an...

Страница 6: ...Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Con...

Страница 7: ...lume is not less than 50 cubic feet per 1 000 Btu hr 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appl...

Страница 8: ...r into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventila tion for required size of ventilation grills or ducts Figure 2 Ventilat...

Страница 9: ...l burningfireplace thechimney flueandfireboxmustbecleanedofsoot creosote ashes and loose paint by a qualifiedchimneycleaner Creosotewill ignite if highly heated A dirty chimney fluemaycreateanddistrib...

Страница 10: ...o Installing Damper Clamp Accessory for Vented Operation Page 12 Heat Resistant Material A NOTE When installing your gas logs into a manufactured firebox follow firebox manufac turer s instructions fo...

Страница 11: ...ble Flooring Determining Minimum Mantel Clearance When Using a Hood If minimum clearances in Figure 6 are not met you must have a hood When using a hood there are still certain minimum mantel clearanc...

Страница 12: ...eep damper open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue openin...

Страница 13: ...t marked locations using 3 16 drill bit 6 Attach base through holes in back side panels of base to fireplace floor using masonry screws provided in hardware package see Figure 12 7 Connect to gas supp...

Страница 14: ...1 8 NPT Tap Approved Flexible Gas Hose if allowed by local codes PROPANE LP From External Regulator 11 W C to 14 W C Pressure NATURAL From Gas Meter 5 W C to 10 5 W C Pressure We recommend that you in...

Страница 15: ...Valve Location Propane LP Supply Tank Equipment Shutoff Valve CAUTION Avoid damage to gas control Hold gas control with wrench when connecting it to gas piping and or fittings WARNING Testallgaspiping...

Страница 16: ...re gas is turned of to unit WARNING Aqualifiedserviceper son must connect and disconnect gas to appliance Follow all local codes Connect the wires to the valve from the switch assembly as shown in Fig...

Страница 17: ...rent room temperature will be displayed see Figure 21 This icon will always show in the control window as long as the batteries have power Figure 21 Remote Display AAA AAA AAA Figure 20 Battery Instal...

Страница 18: ...NF30INM 30INV 30IPM 30IPV LMF36GTA B LMF36MOA B WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appli ance may resu...

Страница 19: ...Side View Figure 25 Installing Back Left Log Back Left Log D 060 D 018 or D026 Flat Part of Log Log Notch Burner Tube Figure 25A Installing Back Left Log Figure 25B Installing Back Left Log D 018 Rear...

Страница 20: ...g Charred Log Top View Figure 27B Installing Charred Log Top Side View Square Grate Log Notch tube on the right side The left side of the burner tube fits into the notch on the back side of this log T...

Страница 21: ...of this log has a rectangular hole that fits over the rectangular peg on the top of the right crossover log Figure 29 Installing Right Split Crossover Log Right Split Crossover Log D 022 Right Front...

Страница 22: ...can be placed on the floor of the fireplace to enhance the look of the log set Use Volcanic Stone to hide wires from switch log to control valve Place switch log so the switch is easy to access Two e...

Страница 23: ...tem and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this appliance with glass doors closed If you operate ap pliance with doors...

Страница 24: ...ob pressed in press and release igniter button on left side of log set This will light pilot The pilot is attached to the front of U shaped burner If needed keep pressing igniter button until pilot li...

Страница 25: ...E Youmustlightthepilotbefore using the hand held remote control unit See Lighting Instructions on Page 23 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adju...

Страница 26: ...FF button or set selector switch in the OFF posi tion Figure 39 Remote Selector Switch in ON Position ON REMOTE OFF PRG NOTICE Duringinitialoperationofnew appliance burning logs will give off a paper...

Страница 27: ...hree prong grounded electrical plug This plug helps protect you against electrical shock Only con nect plug to a properly grounded three prong receptacle Do not cut or remove the grounding prong from...

Страница 28: ...control can operate as a room thermo stat The thermostat can be set to a desired tem perature to control the comfort level in the room To activate press THERMOSTAT button on remote control see Figure...

Страница 29: ...eceiver face plate marked PRG The receiver will beep 3 times to indicate it is ready to accept a new remote transmitter Press the ON OFF button on your re mote and the receiver will beep 4 times to co...

Страница 30: ...eaterclean Inspectthese areas of heater before each use Have heater inspected yearly by a qualified serviceperson Heatermayneedmore frequentcleaningduetoexcessivelint from carpeting bedding material p...

Страница 31: ...ic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C For purpose of input adjustment To Thermopile To AUTO Terminal on Switch To OFF Terminal on Switch WIRING DIAGRAM REM...

Страница 32: ...only 1 Reconnect Igniter cable 2 Free Igniter cable if pinched by any metal or tubing Keep Igniter cable dry 3 Replace Igniter cable 4 Replace Igniter 5 Replace pilot assembly 6 Replace pilot assembly...

Страница 33: ...30 or replace ODS pilot as sembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Replace control valve One or both burners do not light after ODS pilot is lit 1 Inlet...

Страница 34: ...ny 3 Observe minimum installation clearances see Pages 9 11 4 Clean burners see Cleaning and Maintenance Page 30 or replace burner orifice s White powder residue forming within burner box or on adjace...

Страница 35: ...Stop using odor caus ing products while appliance is running 2 Refill supply tank propane LP only 3 Locate and correct all leaks see Checking Gas Connec tions Page 15 Appliance shuts off in use ODS op...

Страница 36: ...2 33 11 30 12 13 14 15 16 17 18 19 10 20 21 22 23 24 25 26 27 34 28 29 Cat No Model F2088 MNF24INM F2091 MNF24IPM F2094 MNF30INM F2097 MNF30IPM F2089 MNF24INV F2092 MNF24IPV F2095 MNF30INV F2098 MNF30...

Страница 37: ...J6127 Orifice Holder 90 Degree 1 16 J8098 Orifice 0 052 1 321 mm 1 J8169 Orifice 028 Pan 1 17 J1958 Screw HWH AB 8 18 X 38 4 18 J5416 Venturi Tube 1 19 J5456 Burner Gasket 1 20 J4596 Igniter Electron...

Страница 38: ...J6517 D 018 J6528 D 026 Log Back Left 1 3 J6698 D 059 J6518 D 017 J6529 D 025 Log Front Left 1 4 J6519 D 020 J6519 D 020 J6519 D 020 Log Charred 1 5 J6699 D 063 J6520 D 021 J6530 D 028 Log Middle Spl...

Страница 39: ...on Page 40 of this manual KEY NO CAT NO Log Id CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8245 D 061 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8246 D 060 J8254 D 018 J8260 D 026 Log Back Left...

Страница 40: ...y ques tions concerning the installation or application of this appliance please contact your dealer SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed igniti...

Страница 41: ...og sets VOLCANIC STONE Cat No 80L42 Model FDVS For all models Order when additional volcanic stone is desired EMBER KITS Platimun Embers Cat No J6207 Glowing Embers rockwool Cat No J6208 FLOOR MEDIA K...

Страница 42: ...mote control RECEIVER AND REMOTE CONTROL KIT Cat No F1079 Model TSRC For all Remote Ready Models Allows the burner system to be operated in a manually or thermostatically controlled mode Remote is pro...

Страница 43: ...roduce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d da...

Страница 44: ...number Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name Innovative Hearth Products IHP reserves the right to make changes at any time without notice in desig...

Отзывы: