background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

3

3

INNOVATIVE HEARTH PRODUCTS

  •

  LINEAR ELECTRIC FIREPLACE

  •

  INSTALLATION INSTRUCTIONS

Installation must conform to local codes. 

In the absence of local codes, electrical 

wiring and grounding must comply with 

the National Electrical Code ANSI/ NFPA 

70 - latest edition.  In Canada, the cur-

rent CSA C22-1 Canadian Electrical Code 

- latest edition.

In selecting this Innovative Hearth Products linear electric fireplace, you have chosen 

the finest and most dependable fireplace found anywhere.  A beautiful and prestigious 

addition to the finest homes.  Welcome to a Family of hundreds of thousands of satis-

fied IHP Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual.  Please 

pay special attention to the safety instructions provided in this manual.  The instruc-

tions included here will assure that you have many years of dependable and enjoyable 

service from your IHP product.

TABLE OF CONTENTS

Important Safety Information ........... Page 2
Packaging List .................................. Page 3
Introduction ..................................... Page 3
General Information ......................... Page 3
Locating Fireplace ............................ Page 3
Tools/Supplies Required .................. Page 3
Framing Specifications ..................... Page 4
Fireplace Specifications .................... Page 4
Clearances ....................................... Page 5
Pre-installation ................................. Page 5
Installation Steps ............................. Page 5
Electrical Connections ...................... Page 6
Final Finishing .................................. Page 6
Break-In Period ................................ Page 6
On/Off Switch ................................... Page 6
Remote Control Operation ............... Page 7
Operation Modes .............................. Page 7
Maintenance ..................................... Page 8
54" Fireplace Specifications .............. Page 9
60" Fireplace Specifications .............. Page 10
Troubleshooting ............................... Page 11
Exploded Diagram Key ..................... Page 12
Available Replacement Parts ............ Page 12
Exploded Diagram ............................ Page 13 
Electrical Diagram ............................ Page 14 
Warranty .......................................... Page 15

PACKAGING LIST

This assembled Electric Room Heater is 

packaged with:

•   One  accessory  package  located  in  the 

firebox, containing; 

1. One Installation and Operation Manual.

2. One Warranty Certificate (in manual)

3. One Remote Control.

GENERAL INFORMATION

Power Supply Wire Specifications

120 Volt, 60 Hz, 1500 Watts:

Power is supplied to the fireplace through a 

120Volt, 60Hz receptacle located withing reach 

of the powercord provided with the fireplace. 

If the heater option it to be used we suggest 

that a separate circuit with breaker be used. 

See Table 1.

Power Supply Wire Gage 

Voltage

Wire Gage

Fuse

120 V

14 GA.

15 AMP

Table 1

Figure 1

LOCATING YOUR PRO SERIES ELECTRIC 

FIREPLACE

Your new fireplace may be mounted on or 

recessed into a wall (see 

Figure 1

)

.

When choosing a location for your new fire-

place, ensure that the general instructions are 

followed.  Also, for the best effect, install the 

fireplace out of direct sunlight and away from 

overhead lighting.  See

 Figure 1

.

fireplace shown in gray.

TOOLS AND BUILDING SUPPLIES

NORMALLY REQUIRED

TOOLS:

Phillips Screwdriver

Hammer

Saw And/or Saber Saw

Level

Measuring Tape

Plumb Line

Electric Drill And Bits

Pliers

Square
Gloves

IMPORTANT NOTE: This fireplace system 

is not difficult to install. However, in the 

interest of safety, it is recommended that 

the installer be a qualified or certified 

“tradesman” familiar with commonly 

accepted fireplace installation and safety 

techniques as well as prevailing local 

codes.

BUILDING SUPPLIES:

Framing Materials

Wall Finishing Materials

Top View Showing Approved 

Room Locations of Fireplace

INTRODUCTION

This Electric Fireplace is designed for 

residential applications to be wall mounted 

or framed in as a fireplace.

This appliance has been tested in accor-

dance with UL 2021 and CSA C22.2 No. 

46-M198 standards for fixed and location 

dedicated electric room heaters.

900264-00 Rev. NC  06/14

Содержание Superior ERC4054

Страница 1: ...limited to the fireplace and accessories may void the warranty listings and approvals of this system and could result in an unsafe and potentially dangerous installation Exposed surfaces of the elect...

Страница 2: ...TENDED FOR USE IN BATHROOMS LAUNDRY AREAS OR SIMILAR INDOOR LOCA TIONS NEVER LOCATE THIS APPLI ANCE WHERE IT COULD FALL INTO A BATHTUB OR OTHER WATER CON TAINER DO NOT RUN ELECTRICAL WIRING OR POWER C...

Страница 3: ...15 PACKAGING LIST This assembled Electric Room Heater is packaged with One accessory package located in the firebox containing 1 One Installation and Operation Manual 2 One Warranty Certificate in man...

Страница 4: ...heat NOTE Minimumdistancesbetweenwalls floors and ceilingsmustbeobserved SeeFigure2 Failuretodo so may result in damage to finishing materials on the wall including but not limited to paint and wallpa...

Страница 5: ...nts 120 Volt 60 Hz Rated Wattage 1600 Watts Amperage 13 33 Amps Blower CFM 83 CFM 120 V 5 461 BTU HR b Once the screws are out the top metal bracket will come loose place the bracket away Make sure th...

Страница 6: ...the wiring to the fireplace as shown on Page 14 4 Performafunctiontest SeeFireplaceHeater On Off on Page 7 and Remote Control Operation on Page 8 5 Turn the master power switch to the Off position and...

Страница 7: ...er marks use a damp cloth with a good qualityhouseholdglasscleaner Thefrontglass panel should be completely dried with a clean lint free cloth or paper towel CAUTION Disconnect power before attempting...

Страница 8: ...spond to the transmit ter Do not PRESS the buttons more than once within two seconds for correct operation 3 PowerOnpowerbutton Thepower onbutton at top left corner of the remote is the main ON OFFpow...

Страница 9: ...AR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS 54 1372mm 4 3 4 120mm 22 7 16 596mm 20 508mm 54 LINEAR ELECTRIC FIREPLACE 4 3 4 120mm 22 7 16 596mm 20 508mm 54 1372mm 20 508mm 54 1372mm 4 3 4 120mm 20...

Страница 10: ...2 50mm 6mm 1 5mm 12 4 mm 1 20mm MOUNTING BRACKET mm 4 3 4 120mm 22 7 16 596mm 20 508mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 22 7 16 569 5 3 16 132mm 20 436mm 9 5 8 244mm 17 1 8 436mm 7 1 16 1...

Страница 11: ...mber bed is not glowing LED strip failure or wiring is loose Qualified service technician Inspect all wiring for loose connec tions and repair or replace if neces sary Inspect LED strips and replace i...

Страница 12: ...embly F2046 1 13 Plastic Handle N A 1 14 Left Side Panel N A 1 15 Left Inner Lining Board N A 1 16 Upper Bar N A 1 17 Upper Panel N A 1 18 Remote Receiver Assembly F2048 1 19 Air Outlet Bracket N A 1...

Страница 13: ...IAGRAMS ILLUSTRATIONS NOT TO SCALE 13 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS EXPLODED DIAGRAM WITH AVAILABLE REPLACEMENT PARTS 54 AND 60 MODELS 900264 00 Rev NC...

Страница 14: ...104 C5 104 R5 10K LED1 D1 T1 SS8050 R 180 DS LED3 DS LED2 R 180 1 2 LED HY 2 4 2 1 2 FIRE B 2 4 2 LED6 LED5 T2 SS8050 100 LED8 LED7 R 100 1 2 LED HB 2 4 2 1 2 FIRE Y 2 4 2 12V 12V 12V FAN MOTOR 6 P0 2...

Страница 15: ...ed to normal use All precautions and warnings as described in the instruction owner s manual must be followed c damages caused by failing to provide proper maintenance and service in accordance with t...

Страница 16: ...900264 00 Rev NC 06 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 IHP us com P900264 00 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS...

Отзывы: