![IHP Superior ERC4054 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ihp/superior-erc4054/superior-erc4054_installation-and-operation-instructions-manual_4094726006.webp)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
6
INNOVATIVE HEARTH PRODUCTS
•
LINEAR ELECTRIC FIREPLACE
•
INSTALLATION INSTRUCTIONS
BREAK-IN PERIOD:
During the first few initial uses of this heater,
there may be a release of a slight, harmless odor.
This odor is a normal occurrence caused by the
initial heating of the internal heating elements
and should not reoccur.
WARNING
Electrical wiring must comply
with local building codes and
other applicable regulations to
reduce the risk of fire, electrical
shock and injury to individuals.
IMPORTANT
Any electrical re-wiring of this
appliance must be done by a
qualified electrician.
ELECTRICAL CONNECTIONS FOR
RECESSED FRAMING OPTION
1. Complete the framing opening to the dimen-
sions specified in
Figure 3
. Disable the
blower as shown in
Figure 5
. Insure that the
fireplace is in the off position (see
Figures
7
and
8
).
2. Wire a dedicated, properly fused circuit with
an Amp rating for the appropriate voltage
(120 V - 15 Amps). A dedicated circuit is
required to prevent overloading a house
circuit in cases of having multiple appliances
on the same circuit. Use an outlet that is
protected by a ground fault circuit interrupter
where required by electrical code.
3. Prepare the connections to power receptical:
120 Volt Connections
- Locate the power
cord on the right side of the unit and connect
it to the outlet installed during the framing
(see
Figure 5
)
.
Verify that the power to the
receptacle is off.
Hard wired installation:
Ensure that there is a minimum of 8" of the
service cable for connection to the junction
box on the fireplace.
- Loosen four screws to remove the junction
box cover plate.
- Disconnect and remove the 120 Volt power
cord from the fireplace wires.
- Position the fireplace into the framed-in
opening. Attach fireplace to frame using
nailing flanges provided.
- Complete the wiring to the fireplace as
shown on
Page 14
.
4. Perform a function test. See
Fireplace Heater
On/Off
on
Page 7
and
Remote Control
Operation
on
Page 8.
5. Turn the master power switch to the "Off"
position and cut the power to the breaker
leading to the appliance.
RECESSED INSTALLATION
OPTION
Use the following detailed instructions for
recessed installation.
Installing the fireplace is a two person job.
1. Prepare the wall recess and electrical
receptacle as see in
Figure 3
,
Page 4
. It may
be necessary to shem the wall bracket to the
wall forming the rear of the recess to meet
the minimum distance from the bracket to the
appliance (see
Figure 7
).
2. IMPORTANT: Cut off the breaker leading to
the appliance.
3. Follow the wiring details located in
Figure
11
on
Page 14
.
3. Follow steps 1-5 found under WALL MOUNT-
ING (see
Page 5
). to prepare decorative ele-
ments of the fireplace for installation.
4. Install the mounting bracket on the inside
wall or on the shem.
5. Disable the blower motor and heater by
removing the four screws in the Heater Cutoff
Access Panel and unplugging the wires as
seen in
Figure 5
.
6.
Filp the master power switch to the "ON"
position.
7. Carefully seat the fireplace into the recess
opening near the top of the opening and lower
the appliance so that the mounting brackets
will catch against the brackets at the back of
the fireplace.
8. Turn the breaker supporting the fireplace
back on.
9. Use the supplied remote control to operate
the fireplace. For more information on fireplace
operation, see
Page 8
.
4 5/16”
1”
4 1/2”
Back of
recessed
wall
Fireplace
Hanging
bracket
Fireplace
Mounting
bracket
1" (25mm)
4 5/16"
(110mm)
Front of
finished
wall
Back of
recessed
wall
G l a s s
overlap
4 1/8"
(105mm)
Maximum recess depth
Recommended
appliance depth
in wall
Figure 6
Figure 5
When the fireplace is fully installed
using the recess option, the viewing
glass should overlap the top opening
framing approximately 1" (25mm) and
extend to conceal the framing. See
Figure 6
above.
900264-00 Rev. NC 06/14