background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

14

INNOVATIVE HEARTH PRODUCTS

  •

  LINEAR ELECTRIC FIREPLACE

  •

  INSTALLATION INSTRUCTIONS

F1

FUSE2

T6

8050

T5

8050

T7

8050

RELAY-H2

RELAY-H1

RELAY-

MO
TO
R

R3

10K

S1

P-SW

H2

H1

MO
TO
R

C7

35V 680uF

t

25*C,5K

THERMISTOR

1

2

3

4

5

6

SIP2

2.4*7

R7

510

R6

510

R1

2

510

R1

0

510

R1

1

510

1

2

TE

MP

2.4*2

L1

N

H2   PH-

2

6.3*0.

8

6.3*0.

8

MO
TO
R

H1+
FAN

6.3*0.

8

P-NI

6.3*0.

8

D2

1N4007

D3

1N4007

D5

1N4007

VSS

VD
D

20

10

P0.

1

P4.1/AIN1

P4.2/AIN2

P0.

4

P5.

3

P5.

2

P0.5

P0.6

P0.7

8

P5.0

P5.1

SN8P2722

2

15

16

5

12

11

3

9

10

PH-4

6.3*0.

8

N

P-L

6.3*0.

8

TEM

P_BRK

PH-7

6.3*0.

8

PH-6

6.3*0.58

PTC

+5

V

R8

10K

C2

104

C5

104

R5

10K

LED
1

D1

T1

SS8050

R?

180

DS?

LED
3

DS?

LED2

R?

180

1

2

LED-H

Y

2.4*2

1

2

FIRE-B

2.4*2

LED6

LED
5

T2

SS8050

100

LED
8

LED
7

R?

100

1

2

LED-H

B

2.4*2

1

2

FIRE-Y

2.4*2

+12V

+12V

+12V

FAN

MO
TO
R

6

P0.2

7

C4

C6

5v

25V 47uF

104

HS0038

BUZ1

D1

4007

T3

SS8050

R4

510

+5

V

R2

1K

R9

510

LED
6

LED
5

T4

SS8050

180

LED
8

LED
7

R?

100

1

2

LED-M

2.4*2

1

2

LA
MP

2.4*2

+12V

+12V

+12V

C13

400V 22U

6mH

L2

AC

1

V+

2

AC

3

V-

4

D9

2KBP06M

C14

400V 22U

R17

1M

R16

2M

R15

2M

EF1

D7

FR106

D8

P6KE200

C12

16V  10U

4

TNY278PN

TNY1

1

2

5-8

C10

2.2nF/250VAC

C11

2.2nF/250VAC

U1B

LTV817A

U1A

LTV817A

C9

390PF

R13

27

D4

SB3100

D6

12V

L1

3.3uH

C8

100U 16V

+12V

GND

GND

GND

GND

Vin

1

GND

2

Vout

3

7805

IC

1

C1

1KU/16V

C3

104

R1

100/0.5W

+5

V

R14

1K

1

2

7

6

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GN
D

GND

GND

GN
D

ELECTRICAL DIAGRAM

900264-00 Rev. NC  06/14

Содержание Superior ERC4054

Страница 1: ...limited to the fireplace and accessories may void the warranty listings and approvals of this system and could result in an unsafe and potentially dangerous installation Exposed surfaces of the elect...

Страница 2: ...TENDED FOR USE IN BATHROOMS LAUNDRY AREAS OR SIMILAR INDOOR LOCA TIONS NEVER LOCATE THIS APPLI ANCE WHERE IT COULD FALL INTO A BATHTUB OR OTHER WATER CON TAINER DO NOT RUN ELECTRICAL WIRING OR POWER C...

Страница 3: ...15 PACKAGING LIST This assembled Electric Room Heater is packaged with One accessory package located in the firebox containing 1 One Installation and Operation Manual 2 One Warranty Certificate in man...

Страница 4: ...heat NOTE Minimumdistancesbetweenwalls floors and ceilingsmustbeobserved SeeFigure2 Failuretodo so may result in damage to finishing materials on the wall including but not limited to paint and wallpa...

Страница 5: ...nts 120 Volt 60 Hz Rated Wattage 1600 Watts Amperage 13 33 Amps Blower CFM 83 CFM 120 V 5 461 BTU HR b Once the screws are out the top metal bracket will come loose place the bracket away Make sure th...

Страница 6: ...the wiring to the fireplace as shown on Page 14 4 Performafunctiontest SeeFireplaceHeater On Off on Page 7 and Remote Control Operation on Page 8 5 Turn the master power switch to the Off position and...

Страница 7: ...er marks use a damp cloth with a good qualityhouseholdglasscleaner Thefrontglass panel should be completely dried with a clean lint free cloth or paper towel CAUTION Disconnect power before attempting...

Страница 8: ...spond to the transmit ter Do not PRESS the buttons more than once within two seconds for correct operation 3 PowerOnpowerbutton Thepower onbutton at top left corner of the remote is the main ON OFFpow...

Страница 9: ...AR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS 54 1372mm 4 3 4 120mm 22 7 16 596mm 20 508mm 54 LINEAR ELECTRIC FIREPLACE 4 3 4 120mm 22 7 16 596mm 20 508mm 54 1372mm 20 508mm 54 1372mm 4 3 4 120mm 20...

Страница 10: ...2 50mm 6mm 1 5mm 12 4 mm 1 20mm MOUNTING BRACKET mm 4 3 4 120mm 22 7 16 596mm 20 508mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 22 7 16 569 5 3 16 132mm 20 436mm 9 5 8 244mm 17 1 8 436mm 7 1 16 1...

Страница 11: ...mber bed is not glowing LED strip failure or wiring is loose Qualified service technician Inspect all wiring for loose connec tions and repair or replace if neces sary Inspect LED strips and replace i...

Страница 12: ...embly F2046 1 13 Plastic Handle N A 1 14 Left Side Panel N A 1 15 Left Inner Lining Board N A 1 16 Upper Bar N A 1 17 Upper Panel N A 1 18 Remote Receiver Assembly F2048 1 19 Air Outlet Bracket N A 1...

Страница 13: ...IAGRAMS ILLUSTRATIONS NOT TO SCALE 13 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS EXPLODED DIAGRAM WITH AVAILABLE REPLACEMENT PARTS 54 AND 60 MODELS 900264 00 Rev NC...

Страница 14: ...104 C5 104 R5 10K LED1 D1 T1 SS8050 R 180 DS LED3 DS LED2 R 180 1 2 LED HY 2 4 2 1 2 FIRE B 2 4 2 LED6 LED5 T2 SS8050 100 LED8 LED7 R 100 1 2 LED HB 2 4 2 1 2 FIRE Y 2 4 2 12V 12V 12V FAN MOTOR 6 P0 2...

Страница 15: ...ed to normal use All precautions and warnings as described in the instruction owner s manual must be followed c damages caused by failing to provide proper maintenance and service in accordance with t...

Страница 16: ...900264 00 Rev NC 06 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 IHP us com P900264 00 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS...

Отзывы: