background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

5

INNOVATIVE HEARTH PRODUCTS

  •

  LINEAR ELECTRIC FIREPLACE

  •

  INSTALLATION INSTRUCTIONS

MINIMUM CLEARANCES TO COMBUS-

TIBLES

Mantel Clearance: 

Combustible and Non-

combustible mantels may be installed above 

the top of the face of fireplace.

54" Models: ERC4054, Arturcus54, and 

MPE54L

 

 

Description: 54" Linear Electric Fireplace

Shipping Weight: 70 1/2 lbs. (32 KG)

Packaging:

  57” x 6 1/2” x 22 3/8”

  (1448mm x 165mm x 568mm) 

  4.94 cu. ft.

Power Requirements: 

  (120 Volt, 60 Hz.) 

   

Rated Wattage - 1600 Watts

   

Amperage - 13.33 Amps

Blower CFM:  83 CFM

(120 V): 5,461 BTU/HR

FIREPLACE SPECIFICATIONS

This appliance is an electric fireplace designed  

to be framed in with combustible materials (up 

to the edge of the appliance).

When surface mounting the fireplace with 

the heater function enabled, a shelf must be 

a minimum of 15 3/4" above the discharge of 

the heater.

       WARNING 

Do not use this fireplace if any 

part of it has been underwater.  

Immediately call a qualified 

service technician to inspect the 

fireplace and replace any part of 

the electrical system which has 

been under water.

PRE-INSTALLATION

Before You Start

Check appliance for any concealed damage.

DETAILED INSTALLATION STEPS

WALL MOUNTING

1.   Do not connect the appliance until properly 

fixed to the wall and the instruction manual 

is read fully.

2.   Two people are recommended for installation 

of this electric fireplace heater.

3.   Peel off the removable label and the pro-

tective sheet attached to the front tempered 

glass.

4.   To place the decorative crystals media 

follow the steps as given below

a.   To place the crystals, the front glass is 

required to be removed from the heater panel 

body. Unscrew top and side screws which 

hold the glass as shown in 

Figure 4a and 4b

60" Models: 

ERC4060, Arturcus60, and 

MPE60L

 

 

Description: 60" Linear Electric Fireplace

Shipping Weight: 72 3/4 lbs. (33 KG)

Packaging:

  62 3/8” x 6 1/2” x 22 3/8”

  (1584mm x 165mm x 568mm)

  5.3 cu. ft.

Power Requirements: 

  (120 Volt, 60 Hz.) 

   

Rated Wattage - 1600 Watts

   

Amperage - 13.33 Amps

Blower CFM:  83 CFM

(120 V): 5,461 BTU/HR

b.   Once the screws are out the top metal 

bracket will come loose, place the bracket 

away. Make sure the glass is supported 

while doing this. Lift the glass up and out 

from the heater body.

c.   Place the crystals along the light unit in 

desired position.

d.   Put the front glass back and place the 

metal bracket on top of the glass so that 

the bracket secures it. Put the fasten screws 

back. Make sure the screws are tight and 

the glass is secured before continuing with 

the installation.

5.   A minimum recommended viewing distance 

of 15" is recomended.

6.   For installation  of the appliance, care must 

be taken not to damage concealed cables. 

Please be careful while drilling the holes.

7.   This appliance is designed to be permanently 

fixed to a wall at a minimum height of 7 7/8" 

(300mm). The wall bracket must be

  fitted horizontally and the cable routed to 

the bot tom right of the heater.

8.    A minimum height of 15" from bottom of 

heater to floor is recommended for optimum 

viewing of fuel bed. See the 

Figure 2

 for the 

recommended framing dimensions.

10. Carefully lift the heater up ensuring that 

the top rear edge of heater engages the wall 

bracket and is sit ting centrally. Two people 

will make this operation easier.

11.   Gently bring the heater level with the wall 

and hang the heater to the heater bracket. 

Ensure the heater body is locked in with the 

wall bracket.

12.   Attach the bottom bracket to the heater 

panel body and mark the mounting hole; 

remove the heater.

13. Drill the bracket mounting hole and fit the 

wall plug.

14. Refit the heater to the wall and secure the 

bottom bracket using the screws provided 

to permanently fix the heater in place. 

Ensure the heater body is engaged with the 

wall bracket at the top. The heater is now 

ready for use.

Figure 4a

Figure 4b

       WARNING 

The minimum recommended  

safe distance from the fireplace 

to adjacent walls and furnishings 

is 15 3/4" (600mm). 

Fireplace Clearances

WALL

RECESS

Sides

7 7/8" 

(300mm)

0" (0mm)

Floor

7 7/8" 

(300mm)

0" (0mm)

Top

15 3/4" 

(600mm)

0" (0mm)

Rear

0" (0mm)

0" (0mm)

Table 2

900264-00 Rev. NC  06/14

Содержание Arcturus54

Страница 1: ...t limited to the fireplace and accessories may void the warranty listings and approvals of this system and could result in an unsafe and potentially dangerous installation Exposed surfaces of the electronic fireplace adjascent to heaters and blowers may become hot Care should be taken to avoid contact with blower heat discharge outlets such as the one on the top of this fireplace WARNING If the in...

Страница 2: ...NTENDED FOR USE IN BATHROOMS LAUNDRY AREAS OR SIMILAR INDOOR LOCA TIONS NEVER LOCATE THIS APPLI ANCE WHERE IT COULD FALL INTO A BATHTUB OR OTHER WATER CON TAINER DO NOT RUN ELECTRICAL WIRING OR POWER CORD UNDER CARPETING OR COVER WITH THROW RUGS RUNNERS OR SIMILAR MATERIALS FOR 120 VAC POWER CORD AVOID THE USE OF AN EXTENSION CORD BECAUSE THE EXTENSION CORD MAY OVERHEAT AND CAUSE A RISK OF FIRE HO...

Страница 3: ... 15 PACKAGING LIST This assembled Electric Room Heater is packaged with One accessory package located in the firebox containing 1 One Installation and Operation Manual 2 One Warranty Certificate in manual 3 One Remote Control GENERAL INFORMATION Power Supply Wire Specifications 120 Volt 60 Hz 1500 Watts Power is supplied to the fireplace through a 120Volt 60Hz receptacle located withing reach of t...

Страница 4: ... heat NOTE Minimumdistancesbetweenwalls floors and ceilingsmustbeobserved SeeFigure2 Failuretodo so may result in damage to finishing materials on the wall including but not limited to paint and wallpaper These Electric Fireplaces offer a recessed instala tion see Figure 3 that gives the fireplace a more distinguished appearance Recessed framing places the front glass on the unit nearly flush with...

Страница 5: ...ents 120 Volt 60 Hz Rated Wattage 1600 Watts Amperage 13 33 Amps Blower CFM 83 CFM 120 V 5 461 BTU HR b Once the screws are out the top metal bracket will come loose place the bracket away Make sure the glass is supported while doing this Lift the glass up and out from the heater body c Place the crystals along the light unit in desired position d Put the front glass back and place the metal brack...

Страница 6: ... the wiring to the fireplace as shown on Page 14 4 Performafunctiontest SeeFireplaceHeater On Off on Page 7 and Remote Control Operation on Page 8 5 Turn the master power switch to the Off position and cut the power to the breaker leading to the appliance RECESSED INSTALLATION OPTION Use the following detailed instructions for recessed installation Installing the fireplace is a two person job 1 Pr...

Страница 7: ...her marks use a damp cloth with a good qualityhouseholdglasscleaner Thefrontglass panel should be completely dried with a clean lint free cloth or paper towel CAUTION Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire electricalshockorpersonal injury Figure 7 On Fireplace and Heater On Off When the main power switch is turned on power is supplied to the firep...

Страница 8: ...espond to the transmit ter Do not PRESS the buttons more than once within two seconds for correct operation 3 PowerOnpowerbutton Thepower onbutton at top left corner of the remote is the main ON OFFpower button Thiswillturnoffallthefunc tions and the heater will be in standby mode 4 FlamePowerOnbutton Thisbuttoncontrols both the amber and blue color flame Press this buttononcetoturnONtheflameeffec...

Страница 9: ...EAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS 54 1372mm 4 3 4 120mm 22 7 16 596mm 20 508mm 54 LINEAR ELECTRIC FIREPLACE 4 3 4 120mm 22 7 16 596mm 20 508mm 54 1372mm 20 508mm 54 1372mm 4 3 4 120mm 20 508mm 54 1372mm 4 3 4 120mm 22 7 16 596mm 20 508mm 900264 00 Rev NC 06 14 ...

Страница 10: ...m 2 50mm 6mm 1 5mm 12 4 mm 1 20mm MOUNTING BRACKET mm 4 3 4 120mm 22 7 16 596mm 20 508mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 22 7 16 569 5 3 16 132mm 20 436mm 9 5 8 244mm 17 1 8 436mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 22 7 16 56 5 3 16 132mm 20 436mm 9 5 8 244mm 17 1 8 436mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 5 3 16 132mm 20 436 17 1 8 4 900264 00 Rev NC 06 14 ...

Страница 11: ...ember bed is not glowing LED strip failure or wiring is loose Qualified service technician Inspect all wiring for loose connec tions and repair or replace if neces sary Inspect LED strips and replace if necessary 5 Flame sputters Flame motor is defective Qualified service technician Replace flame motor 6 Remote control does not work Low batteries Unit switch and or wall switch in on position Homeo...

Страница 12: ...sembly F2046 1 13 Plastic Handle N A 1 14 Left Side Panel N A 1 15 Left Inner Lining Board N A 1 16 Upper Bar N A 1 17 Upper Panel N A 1 18 Remote Receiver Assembly F2048 1 19 Air Outlet Bracket N A 1 20 Heater Assembly F2049 1 21 Circuit Control Board F2050 1 22 Firebox N A 1 23 Right Lining Panel N A 1 24 Right Side Panel N A 1 25 Heater Cutoff Access Panel N A 1 26 Rocker Switch F2051 1 27 Powe...

Страница 13: ...DIAGRAMS ILLUSTRATIONS NOT TO SCALE 13 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS EXPLODED DIAGRAM WITH AVAILABLE REPLACEMENT PARTS 54 AND 60 MODELS 900264 00 Rev NC 06 14 ...

Страница 14: ... 104 C5 104 R5 10K LED1 D1 T1 SS8050 R 180 DS LED3 DS LED2 R 180 1 2 LED HY 2 4 2 1 2 FIRE B 2 4 2 LED6 LED5 T2 SS8050 100 LED8 LED7 R 100 1 2 LED HB 2 4 2 1 2 FIRE Y 2 4 2 12V 12V 12V FAN MOTOR 6 P0 2 7 C4 C6 5v 25V 47uF 104 HS0038 BUZ1 D1 4007 T3 SS8050 R4 510 5V R2 1K R9 510 LED6 LED5 T4 SS8050 180 LED8 LED7 R 100 1 2 LED M 2 4 2 1 2 LAMP 2 4 2 12V 12V 12V C13 400V 22U 6mH L2 AC 1 V 2 AC 3 V 4 ...

Страница 15: ...ted to normal use All precautions and warnings as described in the instruction owner s manual must be followed c damages caused by failing to provide proper maintenance and service in accordance with the instruc tions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application of the Product This Limited One Year Warranty covers only parts and labo...

Страница 16: ...900264 00 Rev NC 06 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 IHP us com P900264 00 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS ...

Отзывы: