background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

8

8

INNOVATIVE HEARTH PRODUCTS

  •

  LINEAR ELECTRIC FIREPLACE

  •

  INSTALLATION INSTRUCTIONS

  When using the 

remote control

, the 

power 

on/off switch 

on the lower right side of the 

unit must be in the "ON" position.

REMOTE CONTROL OPERATION:

Figure 9

Theis IHP Electric Fireplace is provided 

with an Infrared light Remote Control.  

All functions of the fireplace can be con-

trolled  through the remote control. Note: 

The Effective range of the remote control 

is up to approximately 26 feet (8 meters). 

The functions identified on the remote (see 

Figure 9

)

 are as follows:

A.  POWER BUTTON

   Press once to turn on power to fireplace.

B.  INDICATING LIGHT

    Illuminates when signal is sent. 

C.  FLAME BUTTON

    On/off switch for flame and ember light.

D. AMBER FLAME BUTTON (DIM)

   Reduces brightness of amber light.

E. AMBER FLAME BUTTON (BRIGHTEN)

  Increases brightness of amber light.

F. HEATER ON/OFF

  This button will turn the heater ON and OFF 

independent of the main button.

G. TEMPERATURE ADJUSTMENT BUTTON 

(HIGH)

  Highest heat output, up to 75° F.

H. TEMPERATURE ADJUSTMENT BUTTON 

(LOW.)

  Low heat output, up to 72° F.

I. TEMPERATURE ADJUSTMENT BUTTON 

(ROOM)

  Sets the fireplace to Auto Mode (See 

Opera-

tions

)

J. BLUE FLAME BUTTON (LOWER)

  Reduces brightness of blue light.

K. BLUE FLAME BUTTON (HIGHER)

  Increases brightness of blue light.

POWER

ON/OFF

ON/OFF

AMBER

-5 OFF

+5 MAX

HEATER

ON/OFF

TEMP. CONTROL

HIGH LOW ROOM

BLUE

-5 OFF

+5 MAX

A

C

B

E

F

D

H

G

I

J

K

REMOTE CONTROL

       CAUTIONS 

• Do Not Use Old Batteries With   

New Ones.

• Do Not Use Batteries Other Than 

The Type Specified (2 Ea. AA).

• Ensure Batteries Are Correctly 

Installed In Remote Control. 

FLAME

REMOTE CONTROL OPERATION STEPS:

 

 

1.  For remote to function make sure the heater 

is plugged-in and main power switch located 

on the bottom right hand side is in the “ON” 

position.

 

2. When operating the remote make sure you 

point the remote to the center of the heater unit 

and make sure each time you press the button 

the LED indicator located on top right hand 

corner of the remote blinks. The buzzer inside 

the unit will beep once; if the LED fails to blink 

check the batteries. It takes some time for the 

receiver to respond to the transmit ter. Do not 

PRESS the buttons more than once within two 

seconds for correct operation

 

3.  Power On power button: The power-on button 

at top left corner of the remote is the main ON/

OFF power  button. This will turn off all the func-

tions and the heater will be in standby mode.

 

4.  Flame Power On button: This button controls 

both the amber and blue color flame. Press this 

button once to turn ON the flame effect. Once the 

flame effect is ON use the + and – but tons as 

explained below to adjust the flame brightness 

as desired. Press this button again to turn OFF 

the flame effect. The heater can function even 

when the flame effect is turned off if so desired.

 

REMOTE CONTROL MODEL NO. R-37

PART NO. F2052

The Red Flame +5 or -5 buttons control the 

brightness of the Amber fame. To increase the 

brightness/flame height, press and release the 

flame +5 button. Each time you press this button 

the brightness will increase by a small amount, 

until the maximum is reached.

Press and release the Red Flame -5 button. Each 

time you press this button the brightness will 

decrease by small amount, until the minimum 

brightness is reached.

The Blue Flame +5 or -5 buttons control the 

brightness of the Blue fame. To increase the 

brightness/flame height, press and release the 

Blue Flame +5 button. Each time you press this 

button the brightness will increase by a small 

amount, until the maximum is reached.

To decrease the brightness / flame height, press 

and release the Blue Flame -5 button. Each 

time you press this but ton the brightness will 

decrease by small amount, until the minimum 

brightness is reached.

 

Using these settings you can mix the amber and 

the blue flame to create a realistic or stylized 

flame effect. Color mixes will also be reflected 

in the crystal ember bed for added impact.

 

5. Heater Power Button:  This button is the 

heater ON/OFF button. Press this button to turn 

the heater ON. The heater will always turn on at 

the highest setting. In order to reduce the tem-

perature on the heater press this button again.

 

High Button: Press the high button to switch the 

heater directly to high heat setting of 1500W.

 

Low Button: Press the high button to switch 

the heater directly to low heat setting of 750W.

Room Temp Button: Press the high but ton to 

switch the heater to AUTO Mode (See Opera-

tions, Page 7).

 

6. To turn OFF the heater unit com-

pletely press the Power Button once. 

900264-00 Rev. NC  06/14

Содержание Arcturus54

Страница 1: ...t limited to the fireplace and accessories may void the warranty listings and approvals of this system and could result in an unsafe and potentially dangerous installation Exposed surfaces of the electronic fireplace adjascent to heaters and blowers may become hot Care should be taken to avoid contact with blower heat discharge outlets such as the one on the top of this fireplace WARNING If the in...

Страница 2: ...NTENDED FOR USE IN BATHROOMS LAUNDRY AREAS OR SIMILAR INDOOR LOCA TIONS NEVER LOCATE THIS APPLI ANCE WHERE IT COULD FALL INTO A BATHTUB OR OTHER WATER CON TAINER DO NOT RUN ELECTRICAL WIRING OR POWER CORD UNDER CARPETING OR COVER WITH THROW RUGS RUNNERS OR SIMILAR MATERIALS FOR 120 VAC POWER CORD AVOID THE USE OF AN EXTENSION CORD BECAUSE THE EXTENSION CORD MAY OVERHEAT AND CAUSE A RISK OF FIRE HO...

Страница 3: ... 15 PACKAGING LIST This assembled Electric Room Heater is packaged with One accessory package located in the firebox containing 1 One Installation and Operation Manual 2 One Warranty Certificate in manual 3 One Remote Control GENERAL INFORMATION Power Supply Wire Specifications 120 Volt 60 Hz 1500 Watts Power is supplied to the fireplace through a 120Volt 60Hz receptacle located withing reach of t...

Страница 4: ... heat NOTE Minimumdistancesbetweenwalls floors and ceilingsmustbeobserved SeeFigure2 Failuretodo so may result in damage to finishing materials on the wall including but not limited to paint and wallpaper These Electric Fireplaces offer a recessed instala tion see Figure 3 that gives the fireplace a more distinguished appearance Recessed framing places the front glass on the unit nearly flush with...

Страница 5: ...ents 120 Volt 60 Hz Rated Wattage 1600 Watts Amperage 13 33 Amps Blower CFM 83 CFM 120 V 5 461 BTU HR b Once the screws are out the top metal bracket will come loose place the bracket away Make sure the glass is supported while doing this Lift the glass up and out from the heater body c Place the crystals along the light unit in desired position d Put the front glass back and place the metal brack...

Страница 6: ... the wiring to the fireplace as shown on Page 14 4 Performafunctiontest SeeFireplaceHeater On Off on Page 7 and Remote Control Operation on Page 8 5 Turn the master power switch to the Off position and cut the power to the breaker leading to the appliance RECESSED INSTALLATION OPTION Use the following detailed instructions for recessed installation Installing the fireplace is a two person job 1 Pr...

Страница 7: ...her marks use a damp cloth with a good qualityhouseholdglasscleaner Thefrontglass panel should be completely dried with a clean lint free cloth or paper towel CAUTION Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire electricalshockorpersonal injury Figure 7 On Fireplace and Heater On Off When the main power switch is turned on power is supplied to the firep...

Страница 8: ...espond to the transmit ter Do not PRESS the buttons more than once within two seconds for correct operation 3 PowerOnpowerbutton Thepower onbutton at top left corner of the remote is the main ON OFFpower button Thiswillturnoffallthefunc tions and the heater will be in standby mode 4 FlamePowerOnbutton Thisbuttoncontrols both the amber and blue color flame Press this buttononcetoturnONtheflameeffec...

Страница 9: ...EAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS 54 1372mm 4 3 4 120mm 22 7 16 596mm 20 508mm 54 LINEAR ELECTRIC FIREPLACE 4 3 4 120mm 22 7 16 596mm 20 508mm 54 1372mm 20 508mm 54 1372mm 4 3 4 120mm 20 508mm 54 1372mm 4 3 4 120mm 22 7 16 596mm 20 508mm 900264 00 Rev NC 06 14 ...

Страница 10: ...m 2 50mm 6mm 1 5mm 12 4 mm 1 20mm MOUNTING BRACKET mm 4 3 4 120mm 22 7 16 596mm 20 508mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 22 7 16 569 5 3 16 132mm 20 436mm 9 5 8 244mm 17 1 8 436mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 22 7 16 56 5 3 16 132mm 20 436mm 9 5 8 244mm 17 1 8 436mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 5 3 16 132mm 20 436 17 1 8 4 900264 00 Rev NC 06 14 ...

Страница 11: ...ember bed is not glowing LED strip failure or wiring is loose Qualified service technician Inspect all wiring for loose connec tions and repair or replace if neces sary Inspect LED strips and replace if necessary 5 Flame sputters Flame motor is defective Qualified service technician Replace flame motor 6 Remote control does not work Low batteries Unit switch and or wall switch in on position Homeo...

Страница 12: ...sembly F2046 1 13 Plastic Handle N A 1 14 Left Side Panel N A 1 15 Left Inner Lining Board N A 1 16 Upper Bar N A 1 17 Upper Panel N A 1 18 Remote Receiver Assembly F2048 1 19 Air Outlet Bracket N A 1 20 Heater Assembly F2049 1 21 Circuit Control Board F2050 1 22 Firebox N A 1 23 Right Lining Panel N A 1 24 Right Side Panel N A 1 25 Heater Cutoff Access Panel N A 1 26 Rocker Switch F2051 1 27 Powe...

Страница 13: ...DIAGRAMS ILLUSTRATIONS NOT TO SCALE 13 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS EXPLODED DIAGRAM WITH AVAILABLE REPLACEMENT PARTS 54 AND 60 MODELS 900264 00 Rev NC 06 14 ...

Страница 14: ... 104 C5 104 R5 10K LED1 D1 T1 SS8050 R 180 DS LED3 DS LED2 R 180 1 2 LED HY 2 4 2 1 2 FIRE B 2 4 2 LED6 LED5 T2 SS8050 100 LED8 LED7 R 100 1 2 LED HB 2 4 2 1 2 FIRE Y 2 4 2 12V 12V 12V FAN MOTOR 6 P0 2 7 C4 C6 5v 25V 47uF 104 HS0038 BUZ1 D1 4007 T3 SS8050 R4 510 5V R2 1K R9 510 LED6 LED5 T4 SS8050 180 LED8 LED7 R 100 1 2 LED M 2 4 2 1 2 LAMP 2 4 2 12V 12V 12V C13 400V 22U 6mH L2 AC 1 V 2 AC 3 V 4 ...

Страница 15: ...ted to normal use All precautions and warnings as described in the instruction owner s manual must be followed c damages caused by failing to provide proper maintenance and service in accordance with the instruc tions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application of the Product This Limited One Year Warranty covers only parts and labo...

Страница 16: ...900264 00 Rev NC 06 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 IHP us com P900264 00 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS ...

Отзывы: