background image

ACC-SVN190B-EN

9

Transducer and Tee

W

WA

AR

RN

NIIN

NG

G

R

R--4

41

10

0A

A R

Re

effrriig

ge

erra

an

ntt u

un

nd

de

err H

Hiig

gh

he

err

P

Prre

essssu

urre

e tth

ha

an

n R

R--2

22

2!!

F

Fa

aiillu

urre

e tto

o u

usse

e p

prro

op

pe

err e

eq

qu

uiip

pm

me

en

ntt o

orr cco

om

mp

po

on

ne

en

nttss a

ass

d

de

essccrriib

be

ed

d b

be

ello

ow

w,, cco

ou

ulld

d rre

essu

ulltt iin

n e

eq

qu

uiip

pm

me

en

ntt ffa

aiilliin

ng

g

a

an

nd

d p

po

ossssiib

blly

y e

ex

xp

pllo

od

diin

ng

g,, w

wh

hiicch

h cco

ou

ulld

d rre

essu

ulltt iin

n

d

de

ea

atth

h,, sse

erriio

ou

uss iin

njju

urry

y,, o

orr e

eq

qu

uiip

pm

me

en

ntt d

da

am

ma

ag

ge

e..

T

Th

he

e u

un

niittss d

de

essccrriib

be

ed

d iin

n tth

hiiss m

ma

an

nu

ua

all u

usse

e R

R--4

41

10

0A

A

rre

effrriig

ge

erra

an

ntt w

wh

hiicch

h o

op

pe

erra

atte

ess a

att h

hiig

gh

he

err p

prre

essssu

urre

ess

tth

ha

an

n R

R--2

22

2.. U

Usse

e O

ON

NL

LY

Y R

R--4

41

10

0A

A rra

atte

ed

d sse

errv

viicce

e

e

eq

qu

uiip

pm

me

en

ntt o

orr cco

om

mp

po

on

ne

en

nttss w

wiitth

h tth

he

esse

e u

un

niittss.. F

Fo

orr

ssp

pe

ecciiffiicc h

ha

an

nd

dlliin

ng

g cco

on

ncce

errn

nss w

wiitth

h R

R--4

41

10

0A

A,, p

plle

ea

asse

e

cco

on

ntta

acctt y

yo

ou

urr llo

occa

all T

Trra

an

ne

e rre

ep

prre

esse

en

ntta

attiiv

ve

e..

N

NO

OT

TIIC

CE

E

W

Wiirre

e D

Da

am

ma

ag

ge

e!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w iin

nssttrru

uccttiio

on

nss b

be

ello

ow

w cco

ou

ulld

d rre

essu

ulltt iin

n

d

da

am

ma

ag

ge

ed

d w

wiirre

ess..

U

Usse

e p

prro

ov

viid

de

ed

d w

wiirre

e ttiie

ess tto

o m

ma

akke

e ssu

urre

e w

wiirre

e a

arre

e

sse

eccu

urre

ed

d a

an

nd

d p

prro

otte

ecctte

ed

d ffrro

om

m ssh

ha

arrp

p e

ed

dg

ge

ess a

an

nd

d h

ho

ott

ssu

urrffa

acce

ess..

Install a tee and pressure transducer on the discharge
line service port at each compressor using the
following instructions:

1. Remove cap nut from the unit's high pressure

service port on the discharge line that runs from the
compressor.

Figure 6. High pressure service port

High pressure 

service port

2. Install the transducer onto the Tee port without the

valve core.

Figure 7. Transducer to tee

3. Place the Tee flare nut with valve core depressor on

the unit high pressure tap, where the cap nut was

located.

N

No

otte

e:: If the high pressure service port is on another

Tee, refer to

Figure 8, p. 9

for connection.

Figure 8. Tee and transducer installed on high
pressure service port

4. Tighten flare nut securely to the high pressure

service port and check for leaks.

Wiring

N

NO

OT

TIIC

CE

E

W

Wiirre

e D

Da

am

ma

ag

ge

e!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w iin

nssttrru

uccttiio

on

nss b

be

ello

ow

w cco

ou

ulld

d rre

essu

ulltt iin

n

d

da

am

ma

ag

ge

ed

d w

wiirre

ess..

U

Usse

e p

prro

ov

viid

de

ed

d w

wiirre

e ttiie

ess tto

o m

ma

akke

e ssu

urre

e w

wiirre

e a

arre

e

sse

eccu

urre

ed

d a

an

nd

d p

prro

otte

ecctte

ed

d ffrro

om

m ssh

ha

arrp

p e

ed

dg

ge

ess a

an

nd

d h

ho

ott

ssu

urrffa

acce

ess..

Control Box Wiring

W

WA

AR

RN

NIIN

NG

G

H

Ha

azza

arrd

do

ou

uss V

Vo

olltta

ag

ge

e w

w//C

Ca

ap

pa

acciitto

orrss!!

F

Fa

aiillu

urre

e tto

o d

diisscco

on

nn

ne

ecctt p

po

ow

we

err a

an

nd

d d

diisscch

ha

arrg

ge

e

cca

ap

pa

acciitto

orrss b

be

effo

orre

e sse

errv

viicciin

ng

g cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr

sse

erriio

ou

uss iin

njju

urry

y..

D

Diisscco

on

nn

ne

ecctt a

allll e

elle

eccttrriicc p

po

ow

we

err,, iin

nccllu

ud

diin

ng

g rre

em

mo

otte

e

d

diisscco

on

nn

ne

eccttss a

an

nd

d d

diisscch

ha

arrg

ge

e a

allll m

mo

otto

orr sstta

arrtt//rru

un

n

cca

ap

pa

acciitto

orrss b

be

effo

orre

e sse

errv

viicciin

ng

g.. F

Fo

ollllo

ow

w p

prro

op

pe

err

llo

occkko

ou

utt//tta

ag

go

ou

utt p

prro

occe

ed

du

urre

ess tto

o e

en

nssu

urre

e tth

he

e p

po

ow

we

err

cca

an

nn

no

ott b

be

e iin

na

ad

dv

ve

errtte

en

nttlly

y e

en

ne

errg

giizze

ed

d.. F

Fo

orr v

va

arriia

ab

blle

e

ffrre

eq

qu

ue

en

nccy

y d

drriiv

ve

ess o

orr o

otth

he

err e

en

ne

errg

gy

y sstto

orriin

ng

g

cco

om

mp

po

on

ne

en

nttss p

prro

ov

viid

de

ed

d b

by

y T

Trra

an

ne

e o

orr o

otth

he

errss,, rre

effe

err tto

o

tth

he

e a

ap

pp

prro

op

prriia

atte

e m

ma

an

nu

uffa

accttu

urre

err’’ss lliitte

erra

attu

urre

e ffo

orr

a

allllo

ow

wa

ab

blle

e w

wa

aiittiin

ng

g p

pe

erriio

od

dss ffo

orr d

diisscch

ha

arrg

ge

e o

off

cca

ap

pa

acciitto

orrss.. V

Ve

erriiffy

y w

wiitth

h a

a C

CA

AT

T IIIIII o

orr IIV

V v

vo

ollttm

me

ette

err

rra

atte

ed

d p

pe

err N

NF

FP

PA

A 7

70

0E

E tth

ha

att a

allll cca

ap

pa

acciitto

orrss h

ha

av

ve

e

d

diisscch

ha

arrg

ge

ed

d..

IIn

nsstta

alllla

attiio

on

n

Содержание Odyssey BAYLOAMS20

Страница 1: ...ment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment August 2021 A AC CC C S SV VN N1 19 90 0B B E EN N Installation Guide Head Pressure Control Kit Odyssey Split System with Symbio Controls 13 to 25 Tons B BA AY YL LO OA AM MS S2 20 0 TTA156 180 201 240 251 300 TWA156 180 201 240 MOTOR ON OFF N O OK LINE 120 600VAC P N ICM334 LF MAD...

Страница 2: ...ar r p pr ro op pe er r P PP PE E f fo or r t th he e j jo ob b b be ei in ng g u un nd de er rt ta ak ke en n c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y T Te ec ch hn ni ic ci ia an ns s i in n o or rd de er r t to o p pr ro ot te ec ct t t th he em ms se el lv ve es s f fr ro om m p po ot te en nt ti ia al l e el le ec ct tr ri ic ca...

Страница 3: ...an nd dl li in ng g e et tc c W Wh he er re e l lo oc ca al l r re eg gu ul la at ti io on ns s a ar re e m mo or re e s st tr ri in ng ge en nt t t th ha an n t th he es se e p po ol li ic ci ie es s t th ho os se e r re eg gu ul la at ti io on ns s s su up pe er rs se ed de e t th he es se e p po ol li ic ci ie es s N No on n T Tr ra an ne e p pe er rs so on nn ne el l s sh ho ou ul ld d a al lw...

Страница 4: ...s List 5 General Information 6 Disable Evaporator Defrost Control 6 Installation 7 Controller 7 Transducer and Tee 9 Wiring 9 Control Box Wiring 9 Controller Settings 15 Operation and Troubleshooting 17 Checkout Procedure 17 Table of Contents ...

Страница 5: ...dge Protector 5 4 Screw 8 32 X 1 25 Pan Head 6 4 Screw 10 16 X 50 Hex Head 7 1 Label Information BAYLOAMS20 8 2 Tee Pressure Tap 9 2 Bracket Support 10 2 Harness Low Ambient Kit SOV Item Number Quantity Description 11 1 Harness 2 Kits Jumper 12 1 Harness 24V UC Board to Loam 13 2 Harness Power 14 2 Transducer 15 2 Controller Low Ambient 16 1 Supplemental Wiring Diagram 17 1 Installation Guide 18 1...

Страница 6: ...rost Control I Im mp po or rt ta an nt t For proper operation of the low ambient head pressure control accessory in an Odyssey condenser the Evaporator Defrost Control EDC function MUST be disabled To disable the EDC navigate to the Utilities menu on the Symbio 700 user interface and change the configuration parameter Evaporator Defrost Control to Disabled The Symbio Service and Installation mobil...

Страница 7: ...d p pe er r N NF FP PA A 7 70 0E E t th ha at t a al ll l c ca ap pa ac ci it to or rs s h ha av ve e d di is sc ch ha ar rg ge ed d W WA AR RN NI IN NG G P Pr ro op pe er r F Fi ie el ld d W Wi ir ri in ng g a an nd d G Gr ro ou un nd di in ng g R Re eq qu ui ir re ed d F Fa ai il lu ur re e t to o f fo ol ll lo ow w c co od de e c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s ...

Страница 8: ...CC SVN190B EN Figure 3 Removing the plug screws Remove Screws Figure 4 Mounting the controller Edge Protector Edge Protector Edge Protector Figure 5 Mounted controller I In ns st ta al ll la at ti io on n ...

Страница 9: ...d N No ot te e If the high pressure service port is on another Tee refer to Figure 8 p 9 for connection Figure 8 Tee and transducer installed on high pressure service port 4 Tighten flare nut securely to the high pressure service port and check for leaks Wiring N NO OT TI IC CE E W Wi ir re e D Da am ma ag ge e F Fa ai il lu ur re e t to o f fo ol ll lo ow w i in ns st tr ru uc ct ti io on ns s b ...

Страница 10: ... in kit harness by making an in line connection Securely attach this in line connection to adjacent wiring with wire ties See Figure 11 p 12 c Connect terminal with black and orange wires to the open tab on SOV1 See Figure 11 p 12 d Connect orange wire with stripped end to Rev valve terminal on low amb controller 1 See Figure 11 p 12 4 FOR HEAT PUMP UNITS ONLY connect Switchover valve 2 SOV2 harne...

Страница 11: ...4 gauge wire harness Yellow T3 Orange T2 Brown T1 Brown to Fan Orange to Fan Yellow to Fan Yellow T3 Yellow L3 Orange T2 Orange L2 Brown T1 Brown L1 Low Ambient Controller Brown Yellow Orange Fan Harness I In ns st ta al ll la at ti io on n ...

Страница 12: ...er valve connections 1 Switch Over Valve SOV 1 Black Blue Switch Over Valve SOV2 Figure 11 Switch over connections Black Blue Orange Switch Over Valve SOV1 Switch Over Valve SOV2 Orange Orange Rev Valve I In ns st ta al ll la at ti io on n ...

Страница 13: ...ACC SVN190B EN 13 Figure 12 Jumper harness Low Ambient Controller Red Wire Black Wire Figure 13 Installing 24VAC harness Low Ambient Controller Red Wire Black Wire I In ns st ta al ll la at ti io on n ...

Страница 14: ...14 ACC SVN190B EN Figure 14 Transducer wires Low Ambient Controller Transducer Transducer Low Ambient Controller Black Red Blue White or Green I In ns st ta al ll la at ti io on n ...

Страница 15: ...MP N O T AMBIENT P1 P2 RED P2 B W G P1 B W G Y1 Y2 T STAT 24 VAC COMMON Y2 N O Jumper Position for TWA Models Heat Pump For heat pump applications the heat pump select jumper must be in the N C position see Figure 17 p 15 Figure 17 Jumper position for TWA N C C Y1 REV VALVE P1 P2 BLK HEAT PUMP N O T AMBIENT P1 P2 RED P2 B W G P1 B W G Y1 Y2 T STAT 24 VAC COMMON Y2 N C Operation The low ambient con...

Страница 16: ...OF CONDUCTORS FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT CAUTION UTILICE ÚNICAMENTE CONDUCTORES DE COBRE LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADAS PARA ACEPTAR OTROS TIPOS DE CONDUCTORES SI NO LO HACE PUEDE OCASIONAR DAÑO AL EQUIPO N UTILISER QUE DES CONDUCTEURS EN CUIVRE LES BORNES DE L UNITÉ NE SONT PAS CONÇUES POUR RECEVOIR D AUTRES TYPES DE CONDUCTEURS L UTILISATION DE TOUT AUTRE ...

Страница 17: ... r o ot th he er r i in nd di iv vi id du ua al l w wh ho o h ha as s b be ee en n t tr ra ai in ne ed d i in n h ha an nd dl li in ng g l li iv ve e e el le ec ct tr ri ic ca al l c co om mp po on ne en nt ts s p pe er rf fo or rm m t th he es se e t ta as sk ks s Before leaving the installation observe for correct operation through the desired pressure range see Table 3 p 18 Table 2 Troubleshoot...

Страница 18: ...able 3 Pressure vs voltage Pressure psig Voltage Vdc 0 0 5 50 0 9 100 1 3 150 1 7 200 2 1 250 2 5 300 2 9 350 3 3 400 3 7 450 4 1 500 4 5 O Op pe er ra at ti io on n a an nd d T Tr ro ou ub bl le es sh ho oo ot ti in ng g ...

Страница 19: ...ACC SVN190B EN 19 N No ot te es s ...

Страница 20: ...lease visit trane com or americanstandardair com Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice We are committed to using environmentally conscious print practices ACC SVN190B EN 20 Aug 2021 Supersedes ACC SVN190A EN March 2020 2021 ...

Отзывы: