background image

6

6  Electrical connection

The unit must be connected by a qualified electrician�
The national and international regulations for the installation of electrical 

equipment must be adhered to�

 

Disconnect power� 

 

Connect the unit�

6.1  Wiring

O+ 

actuator 24 V

C1���C4

analogue output current (AC3218)

V1���V4

analogue output voltage (AC3219)

O-

actuator supply 0 V

0 V

analogue output 0 V

A+

AS-i +

A-

AS-i -

E+

external actuator 24 V

E-

external actuator supply 0 V

AC3218

AC3219

Содержание SmartLine AC3218

Страница 1: ...Operating instructions AS i SmartLine module AC3218 AC3219 80255917 00 01 2017 UK...

Страница 2: ...on of an actuator with intrinsic supply 7 6 2 3 Connection of an actuator with separate 24 V supply 8 6 2 4 Electrical connection 0 V terminal 8 6 3 Connection analogue module AC3219 0 10 V 9 6 3 1 Co...

Страница 3: ...or the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Functions and features If the operating instructions or the techni...

Страница 4: ...3218 Rmin for voltage output 1 k AC3219 AS i profile S 7 3 6 Maximum number of modules per AS i system 31 Conversion time digital analogue in the slave with four channels 1 ms Actuator supply from AS...

Страница 5: ...ace between the unit and the top and bottom of the control cabinet to enable air circulation and to avoid excessive heating Take into account the internal heating of all devices when mounting several...

Страница 6: ...stallation of electrical equipment must be adhered to Disconnect power Connect the unit 6 1 Wiring O actuator supply 24 V C1 C4 analogue output current AC3218 V1 V4 analogue output voltage AC3219 O ac...

Страница 7: ...and O are not used with actuators without separate voltage supply 1 Analogue module 2 Actuator without separate supply 6 2 2 Connection of an actuator with intrinsic supply O C1 C4 0 V O A 2 wire actu...

Страница 8: ...not connect the 0 V terminals analogue output 0 V of the respective channels of the current output modules to each other This connection leads to faulty current signals The connection of the 0 V term...

Страница 9: ...3 Connection analogue module AC3219 0 10 V 6 3 1 Connection of an actuator with intrinsic supply O V1 V4 0 V O An actuator with intrinsic supply e g a voltmeter is connected via the terminals V1 4 and...

Страница 10: ...be taken from the terminals V1 V4 and 0 V The terminals O and 0 V must be con nected to each other via a link 1 Analogue module 2 Actuator with separate supply 7 Parameter setting Parameter bit Desig...

Страница 11: ...711 2CEC on above nominal range 11 5 V 11500 2CEC flashing overflow 8 3 Transmission time of the analogue values The transmission time of the analogue values depends on the conversion time of the digi...

Страница 12: ...eripheral fault is indicated if at least one of the analogue signals is outside the value range LED yellow DIAG DIAG lights DIAG flashes DIAG off Internal diagnostics no fault internal fault replace m...

Страница 13: ...13 UK 11 Scale drawing 108 25 4 93 126 LED 35...

Отзывы: