27
UK
CAUTION
For medium temperatures above 50 °C (122 °F) some parts of the housing can
heat up to over 65 °C (149 °F)�
►
Do not press the pushbuttons manually� Instead use another object (e�g�
ballpoint pen)�
10.1 Parameter setting in general
1� Change from the RUN mode to the main menu and
selection of the requested parameter
[Mode/Enter]
2� Acknowledge the set parameter value
[Set]
3� Change the setting mode
[Set] > 5 s
4� Modification of the parameter value
-incrementally by pressing once
-continuously by keeping the button pressed
To reduce the value: let the display move to the
maximum setting value� Then the cycle starts
again at the minimum setting value�
[Set]
5� Acknowledge the set parameter value
[Mode/Enter]
6� Return to the RUN mode
> 30 seconds (timeout)
or
[Mode/Enter] until the RUN
mode is reached�
10.1.1 Change to the menu "Extended functions"
1� Change from the RUN mode to the main menu and
selection of the parameter EF
[Mode/Enter]
2� Change to sub-menu EF
[Set]