Operating instructions FX460
7
With regard to installation conditions, wiring, environmental conditions as well as
screening and grounding of connected cables, the general standards for control
cabinet construction in the machine industry as well as the manufacturer's specific
screening instructions apply�
5 General
The device is designed as panel-mounting display unit for HTL pulses�
5.1 Operating mode
In general, all functions can be configured in the parameter menu� The device can
be operated in the following display modes:
●
Speed:
Indication of rotational speed (RPM), operation as tachometer or for frequency
measurement� Only input A is active� Input B is unused�
●
Process time:
Operation as baking time or processing time display (reciprocal rotational
speed)� Only input A is active� Input B is unused�
●
Timer:
Operation as stop watch� Start and stop functions are freely configurable�
Depending on the parameter setting, only input A or inputs A and B are active�
●
Counter:
Operation as position display, pulse, totalisator, differential, up or down counter�
Inputs A and B are active�
●
Velocity:
Speed indication from operating time measurement� Input A serves as start
input and input B as stop input�
In addition, the devices can be used for control and regulating purposes�
Monitoring limits such as maximum speed, minimum speed, standstill or a window
function is also possible�
Function diagram