Operating instructions FX460
28
DECIMAL POINT
This setting defines the position of the decimal point�
NO
No decimal point
0000000�0
Decimal point at the specified position
000000�00
Decimal point at the specified position
00000�000
Decimal point at the specified position
0000�0000
Decimal point at the specified position
000�00000
Decimal point at the specified position
00�000000
Decimal point at the specified position
0�0000000
Decimal point at the specified position
BATCH / TOTAL MODE
Setting of the batch counter / total counter�
The function of batch counting in dependence on the preselection value (PRESELECTION 1���3) is only
possible in connection with the switch condition automatic setting to zero (RESULT>=PRES->0) or setting
to counter value (RESULT<=0->SET)�
If BATCH / TOTAL MODE is activated, the batch counter or the total counter can be assigned to the
respective preselection value (PRESELECTION 1���4) via the source (SOURCE 1���4)�
Example: batch counter
If the batch counter is to be increased by 1 every 1000 pulses, the following parameters have to be set:
– a preselection value (e�g� PRESELECTION 1) to 1000
– the respective source (SOURCE 1) to MEASUREM� RESULT
– the respective switching condition (MODE 1) to RESULT>=PRES->0
– BATCH MODE to INCREMENT BATCH
If after a batch of 33 an output is to be switched, the following parameters have to be set:
– a preselection value (e�g� PRESELECTION 2) to the value 33
– the respective source (SOURCE 2) to BATCH COUNTER
– the switching condition (MODE 2) to display value greater than or equal to (RESULT >=PRES)�
Example: total counter
For total counter, BATCH / TOTAL MODE has to be set to TOTAL COUNTER� Total counter and main
counter run in parallel�If the total counter, on reaching 4000, is to be automatically reset to 0, the following
parameters have to be set:
– a preselection value (e�g� PRESELECTION 3) to 4000
– the respective source (SOURCE 3) to TOTAL COUNTER
– the respective switching condition (MODE 3) to RESULT>=PRES->0
OFF
Neither batch counter nor total counter
INCREMENT BATCH
Batch counter is incrementing�
DECREMENT BATCH
Batch counter is decrementing�
USE INPUTS ONLY
Batch counter only operates via external control commands (see
COMMAND menu)�
TOTAL COUNTER
Total counter activated