8.5.3 Fault diagnosis
In case of a fault switch the safety relay off and on again!
LED display
Cause of the fault
Troubleshooting
• No voltage supply
• Overvoltage
►
Check wiring
►
Check power supply
• Short circuit
• Wire break
►
Check wiring
• Short circuit
• Wire break
►
Check wiring
• Short circuit
• Wire break
►
Check wiring
• Feedback contacts open
• Wire break
►
Check wiring
• When voltage is applied:
feedback contacts open
►
Check output circuit
►
Check feedback contacts
►
Exchange external contactor
• Wiring fault
• Missing link Y4/Y5
• Short circuit
►
Check wiring