8 Connection - Function - Fault diagnosis
The safety relay can be connected or used in different ways:
1� Safety relay for fail-safe sensors/switches with 2 PNP outputs (e�g� GM701S)�
2� Safety relay for clocked fail-safe sensors (e�g� GM504S)�
3� Relay for two-hand control to EN 574 with electronic sensors�
4� Relay for two-hand control to EN 574 with mechanical switches / safety relay
for mechanical switches or 2-channel fail-safe sensors/switches (e�g� ESPE to
EN 61496-1) with contact output with simultaneity monitoring�
5� Safety relay for e-stop, for two-channel fail-safe sensors/switches (e�g� ESPE
to EN 61496-1) with contact output without simultaneity monitoring (indefinite
simultaneity) or for mechanical switches�