background image

 

IO-Link master with USB interface 1 port IP 65 / IP 67 

 

Installation 

Content 

Install the device ....................................................................................................................................... 9 

60816 

 

The responsibility for the compliance with the requirements concerning mounting of the device 
in the application with regard to shock, vibration, acceleration and weight lies with the system 
architect. 

  

 

5.1 

Installing the device 

60817 

►  When installing the device in the automation system, use only suitable mounting accessories (e.g. 

cable ties). 

►  When using cable ties, use the recesses of the machine as a guide (see figure). 

  

 

►  When attaching the cable ties, make sure that the status LEDs are not covered. 

  

 

Fig.: Correct placement of the cable ties 

Содержание AL1060

Страница 1: ... 80296561 02 04 2021 Operating instructions IO Link master with USB interface 1 port IP 65 IP 67 AL1060 Firmware 3 2 x English ...

Страница 2: ...allation 9 5 1 Installing the device 9 6 Electrical connection 10 6 1 Overview 11 6 2 Connecting the IO Link device 11 6 3 Connecting the device 11 7 Operating and display elements 12 7 1 LED PWR 12 7 2 LED IO Link 12 7 3 LED DI DO 12 8 Set up 13 8 1 Installing LR DEVICE 13 9 Parameter setting 14 9 1 First steps 14 9 1 1 Online parameter setting 15 9 1 2 Offline parameter setting 15 9 2 Port 1 Con...

Страница 3: ...in 2 19 9 5 Info Showing device information 19 9 6 Firmware Reseting device to factory settings 19 9 7 Firmware Rebooting the device 20 9 8 IO Link device Accessing parameter values 20 10 Troubleshooting 21 11 Maintenance repair and disposal 22 11 1 Updating firmware 22 11 2 Cleaning process 22 ...

Страница 4: ...can result in malfunction or interference Information Supplementary note Request for action Reaction result see abc Cross reference 123 0x123 0b010 Decimal number Hexadecimal number Binary number Designation of pushbuttons buttons or indications 1 2 Warnings used 58278 WARNING Warning of serious personal injury Death or serious irreversible injuries may result CAUTION Warning of personaly injury S...

Страница 5: ...IP 65 IP 67 5 1 3 Modification history 34492 Version Topic Date 00 New creation of document 10 2020 01 Added note on additional power supply Corrected max current of IO Link devices 11 2020 02 Corrected minimum requirements Windows 10 04 2021 ...

Страница 6: ...this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Functions and features p 7 If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur...

Страница 7: ...tended use 60810 The device may only be used for the following purposes As an IO Link master to configure and control the connected IO Link device As a gateway between an IO Link device and a computer The device is designed for use outside of a control cabinet ...

Страница 8: ...tal input output 60813 Pin 2 of the IO Link port can be configured either as an additional digital input or digital output The additional digital input output refers to the potential of the device supply pin 3 4 3 Visual indication 60814 The device displays the following indications Status of the voltage supply Status of the IO Link port Signal status of the digital input output 4 4 Parameter sett...

Страница 9: ...n with regard to shock vibration acceleration and weight lies with the system architect 5 1 Installing the device 60817 When installing the device in the automation system use only suitable mounting accessories e g cable ties When using cable ties use the recesses of the machine as a guide see figure When attaching the cable ties make sure that the status LEDs are not covered Fig Correct placement...

Страница 10: ...ance requirements of the standard EN 61076 2 101 To adhere to the protection rating only cables certified to this standard must be used The system architect undertakes to ensure the ingress resistance of cables they have cut to length Carry out the fitting according to the indications of the cable manufacturer The maximum permitted tightening torque is 1 8 Nm During installation place the M12 conn...

Страница 11: ...20 Connect the device to the USB interface of the PC via port USB If the IO Link device requires more than 150 mA 10 either temporarily or permanently the power supply via port USB is not sufficient Connect the device to supply voltage 24 V DC 20 30 SELV PELV via port AUX Recommended maximum cable length 3 m Ensure correct wiring Do not connect additional supply voltage to port USB If the addition...

Страница 12: ... operating mode pin 4 disabled or operating mode pin 4 DI DO signal level OFF orange on operating mode pin 4 DI DO signal level ON green flashing operating mode pin 4 IO Link connection to the IO Link device is being established or no IO Link device connected on operating mode pin 4 IO Link connection to the IO Link device is OK red flashing operating mode pin 4 IO Link connection to IO Link devic...

Страница 13: ... Windows 10 Once connected to the USB interface the operating system recognises the device and automatically installs the necessary USB drivers Further steps Connect the IO Link device to the IO Link master Electrical connection p 10 The IO Link master supplies the connected IO Link device with operating voltage 8 1 Installing LR DEVICE 60825 The ifm software LR DEVICE version 1 7 x or higher art ...

Страница 14: ...tings 19 Firmware Reboot the device 20 IO Link device Access parameter values 20 60826 9 1 First steps 60827 Requirements LR DEVICE is correctly installed Install LR DEVICE p 13 Start LR DEVICE The user interface of the LR DEVICE appears Optional Update IODD library Click on the Read from device symbol LR DEVICE searches for connected devices LR DEVICE displays the IO Link master AL1060 under ONLI...

Страница 15: ...s in your plant During the parameter setting process the IO Link master and the IO Link device stay in operating mode They continue to monitor with the existing parameters until the parameter setting has been completed 9 1 2 Offline parameter setting 60829 The AL1060 supports offline parameter setting The user creates a configuration for the IO Link master and the connected IO Link devices without...

Страница 16: ...iption Possible values Port1 Mode Pin4 US Operating mode of the IO Link port pin 4 Disabled No data transmission DI Digital input DO Digital output IO Link IO Link Port 1 Cycle time actual Current cycle time of the data transmission between IO Link master and IO Link device read only Value in microseconds Port1 Cycle time preset Requested cycle time of the data transmission between the IO Link mas...

Страница 17: ... parameters as required Parameter Description Possible values Validation Data Storage Supported IO Link standard and behaviour of the IO Link master when a new IO Link device is connected to the port No check and clear Note Device validation and data storage p 18 Type compatible V1 0 device Type compatible V1 1 device Typ compatible V1 1 device with Backup Restore Type compatible V1 1 device with ...

Страница 18: ...device yes test the compatibility with IO Link standard V1 1 no no Type compatible V1 1 device with Backup Restore yes test the compatibility with IO Link standard V1 1 and identity of design vendor ID and device ID yes automatic storage of the parameter values changes of the current parameter values will be stored yes recovery of the parameter values when connecting an identical IO Link device wi...

Страница 19: ... read the general information of the ifm IO Link master Select Info menu The menu page shows the current settings Name Description Possible values Product code Article number of the IO Link master AL1060 Device familiy Device family of the IO Link master IO Link master Vendor Manufacturer ifm electronic gmbh SW Revision Firmware of the IO Link master HW Revision Hardware version of the IO Link mas...

Страница 20: ...ut the available parameters and data structures of the IO Link device IO Device Description IODD of the IO Link device Requirements IO Link device correctly connected to the IO Link master Connect the device p 11 Operating mode of pin 4 of the IO Link port is IO Link Port 1 Configure operating mode pin 4 p 16 Scan network for devices LR DEVICE detects the IO Link master LR DEVICE automatically det...

Страница 21: ...t IP 65 IP 67 21 10 Troubleshooting 60838 Warnings faults and status messages are indicated by the status LEDs Operating and display elements p 12 LR DEVICE provides additional status information in the online mode LR DEVICE software manual ...

Страница 22: ...ware file has been downloaded www ifm com New firmware file has been unzipped bin Start LR DEVICE Scan network for devices LR DEVICE detects the IO Link master Under ONLINE Click on the IO Link master LR DEVICE reads the device and displays current parameter values Click on the Load parameter from file symbol The file explorer is displayed Select new firmware file bin and click Open to confirm you...

Отзывы: