Operating instructions 

Electronic manometer

PG24xx

706086 / 00

 

02 / 2019

Содержание PG24 Series

Страница 1: ...UK Operating instructions Electronic manometer PG24xx 706086 00 02 2019...

Страница 2: ...lanation of the main menu 13 8 3 Menu structure level 2 extended functions 14 8 4 Explanation of the menu level 2 15 9 Parameter setting 16 9 1 General parameter setting 16 9 2 Configuration of the di...

Страница 3: ...ons Only use the product for its intended purpose 3 Functions and features Only use the product for permissible media 3 1 Applications If the operating instructions or the technical data are not adher...

Страница 4: ...0 100 1450 350 5070 PG2454 1 10 16 14 4 145 232 50 725 150 2175 PG2455 1 4 6 4 14 5 58 92 8 30 435 100 1450 PG2456 0 125 2 5 4 1 8 36 25 58 00 20 290 50 725 PG2457 0 05 1 1 6 0 72 14 5 23 20 10 145 30...

Страница 5: ...d from an isolating transformer having a secondary listed fuse rated either a max 5 amps for voltages 0 20 Vrms 0 28 3 Vp or b 100 Vp for voltages of 20 30 Vrms 28 3 42 4 Vp 4 Function 4 1 Processing...

Страница 6: ...ally open OU1 Hno fig 1 Hysteresis function normally closed OU1 Hnc fig 1 First the set point SP1 is set then the reset point rP1 with the requested difference Window function normally open OU1 Fno fi...

Страница 7: ...ameter AEP defines at which measured value the output signal is 20 mA 4 mA at InEG Minimum distance between ASP and AEP 25 of the final value of the measuring range Factory setting Measuring range sca...

Страница 8: ...the extended display range The zero point calibration COF influences the calibration of the curve of measured values Recommendation set COF to 0 9 4 1 COF then calibrate the curve of measured values A...

Страница 9: ...uitable for process connections with cylindrical pipe thread e g flat seals or double edge sealing rings 2 Installation with sealing tape Insert the unit and the sealing tape into the process connecti...

Страница 10: ...equipment must be adhered to Voltage supply according to EN 50178 SELV PELV Disconnect power Connect the unit as follows OUT1 positive switching OUT1 negative switching Pin 1 Ub Pin 3 Ub Pin 4 OUT1 Bi...

Страница 11: ...LEDs LED 1 system pressure of the digital display in bar LED 2 system pressure of the digital display in mbar LED 3 system pressure of the digital display in PSI LED 4 system pressure of the digital d...

Страница 12: ...ouch buttons are activated simply by touching deactivated by releasing the touch button The touch button must be completely covered to be activated Slow covering e g liquid flows over the display does...

Страница 13: ...mally open no or normally closed nc OU2 Output function for OUT2 Analogue signal for the current system pressure 4 20 mA I 20 4 mA InEG tCOF Teach zero point calibration tASP Teach analogue start poin...

Страница 14: ...14 8 3 Menu structure level 2 extended functions 1 Change to the main menu...

Страница 15: ...d value at which 20 mA is provided 4 mA if OU2 InEG HI Maximum value memory for system pressure LO Minimum value memory for system pressure COF Zero point calibration dS1 Switch on delay for OUT1 dr1...

Страница 16: ...5 s setting value is changed step by step by touching briefly several times or continuously by touching permanently Mode Enter Set Numerical values are incremented continuously To reduce the value let...

Страница 17: ...lashes the current system pressure continues to be displayed After 10 s the display goes out for approx 1 s Release Mode Enter and Set again Both buttons must be released within 4 s If this does not h...

Страница 18: ...owing applies 0 ASP value 100 AEP value Note display 0 does not mean that no pressure is applied to the system Select diS and set the update rate of the display d1 update of the measured values every...

Страница 19: ...ort pressure peaks the digital display and LED ring show the indication for a longer time Pdir The LED ring indicates the trend of the pressure changes 5 LEDs below the pointer for rising pressure 5 L...

Страница 20: ...current system pressure is defined as end value for the analogue signal ASP AEP can only be set automatically within defined limits 10 3 Setting ranges If automatic setting is carried out at an inval...

Страница 21: ...value between 0 01 and 30 s dAP value response time between pressure change and change of the switching status in seconds dAP influences the switching frequency fmax 1 2dAP dAP also has an effect on...

Страница 22: ...is displayed b Change a 2nd point on the curve of measured values Set a second defined reference pressure in the system Touch Set for 5 s The pressure measured by the unit is displayed Touch Set until...

Страница 23: ...elements Reset the lag indicator if LED HInd or LInd Touch Set for 1 second The two lag indicator LEDs jump to the current position of the pointer 10 1 Read set parameters Touch Mode Enter until the...

Страница 24: ...2 PSI 6 2322 0 2316 0 1959 363 2322 3 PG2453 bar 0 90 40 00 1 00 39 90 1 00 33 75 5 25 40 00 0 05 PSI 13 0 580 0 14 5 578 5 14 5 489 5 76 0 580 0 0 5 PG2454 bar 0 96 16 00 1 00 15 96 1 00 13 50 1 50...

Страница 25: ...12 5 337 5 50 0 400 0 0 5 inH2O 4 6 160 6 5 0 160 2 5 0 135 6 20 0 160 6 0 2 PG2489 mbar 4 6 160 0 5 0 159 6 5 0 135 0 20 0 160 0 0 2 inH2O 1 84 64 24 2 00 64 08 2 00 54 24 8 00 64 24 0 08 P step incr...

Страница 26: ...F tCOF 0 0 ASP tASP 0 VMR AEP tAEP 100 VMR Uni bAr mbAr SELd P dS1 0 0 dr1 0 0 P n pnp dAP 0 06 dAA 0 03 dis d2 LED SPRP CP1 0 00 CP2 0 00 the indicated percentage of the final value of the measuring...

Страница 27: ...27 UK More information at www ifm com...