9.2 Configuration of the digital display (optional)
►
Select [Uni] and set the unit of measurement:
-[bAr] / [mbAr]�
-[PSI] / [inHO]�
The unit of measurement available for selection depends on the
device�
►
Select [SELd] and set type of indication:
-[P]: system pressure in the unit set in Uni�
-[P%]: system pressure in % of the set scaling of the analogue output;
the following applies: 0 % = ASP value / 100 % = AEP value�
Note: display “0 %” does not mean that no pressure is applied to the
system�
►
Select [diS] and set the update rate of the display:
-[d1]: update of the measured values every 50 ms�
-[d2]: update of the measured values every 200 ms�
-[d3]: update of the measured values every 600 ms�
-[OFF] = The measured value display is deactivated in the Run
mode� Touching one of the buttons indicates the current measured
value for 15 s� Touching the [Mode/Enter] button again activates the
display mode� The indicator LEDs remain active even if the display is
deactivated�