Technical data
Input/output module CR2013
22
Housing
Dimensions
Device connection
Operating temperature
Storage temperature
Protection rating,
protection class
Operating voltage (U
B
)
Current consumption
Indicators
Interface
Baud rate
Communication profile
Device profile
CAN
Binary inputs
Switch-on level
Switch-off level
Detectable pulses
without filter function
with filter function
Analog inputs
Input voltage
Input impedance
Resolution
Accuracy
Sensor supply I
max
Binary outputs
Switching voltage
Switching current
Overload current
Total current
PWM outputs
Output frequency
PWM pulse/break ratio
Resolution
8-channel splitter box made of polyamide (PA)
with integrated electronics, fully potted
152 mm x 60 mm x 22 mm (L x W x H)
cable connection 2m
2 x 1.5mm² (operating voltage) / 3 x 0.5mm² (CAN interface)
M12 connector for inputs/outputs
-25...85 °C
-40...90 °C
IP 67
III
10...30 V DC, SELV
≤
100 mA, without external load
LED green: Run LED
LED red: diagnostic LED
LED yellow: input/output status
CAN interface - ISO 11898
10 Kbits/s - 1 Mbits/s
CANopen
I/O module to CiA DS401, CiA DS301 V3.0
Full-CAN 2.0
sockets 1, 3, 5, 7
0.4...0.7 U
B
0.2...0.24 U
B
ti
≥
2 ms (typ.)
ti
≥
20 ms (typ.)
sockets 2, 4, 6, 8
0...10 V DC
≥
50 k
Ω
10 bits
≤
± 1.0% FS
The output impedance of the analog source should be
max. 10 k
Ω
300 mA
sockets 2, 4, 6, 8
semiconductor outputs, short-circuit and overload protected,
diagnostic capability
10...30 V DC
max. 4 A
(loads < 900 mA can generate the error signal "wire break")
4,4 A
16 A
sockets 2, 4, 6, 8
20...200 Hz
1...100%
1%
With a configuration as PWM output the status LED is
permanently lit for PWM values
≥
1%
No diagnosis is possible