Vacuum the AC as recommended.
Vacuuming
Air and humidity left inside the refrigerant
circuit can cause compressor malfunction.
After having connected the indoor
and outdoor units, remove the air
and humidity from the refrigerant
Circuit by using a vacuum pump.
Note
Only persons or companies qualified
and experienced in the installation, service
and repair of refrigerant products should
be permitted to do so. The purchaser must
Ensure that the person and/or company
who is to install, service or repair this
Air conditioner has qualifications
and experience in refrigerant products.
After completing the piping, purge the air
from the connected pipe and cooling unit.
If this is not done, the discharge pressure
will rise abnormally and may damage the
refrigerating-cycle unit.
Remove the valve cap of the valve core.
Air purging using a vacuum pump
Connect one end of the charge hose
to the vacuum pump and the other end
to the service valve with the large diameter
pipe side service valve.
Fully open the LO knob of the manifold
valve and energize both solenoid valves.
Run the vacuum pump.
Close the LO knob of the manifold valve.
Stop the vacuum pump.
Remove the valve cap from the spindle
of the service valve.
Turn the spindles of the large and small
diameter pipe side service valves fully
counter-clockwise until they are securely
tightened. Then, retighten them more
than 10 degrees using a hexagon wrench
key of 4/5 mm.
Disconnect the charge hose from
the service valve.
34
Содержание FASTCOOL CI12
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ...For Internal use only IU221OTUSM012 REV D...
Страница 5: ...01...
Страница 6: ...02...
Страница 14: ...10...
Страница 16: ......
Страница 18: ...Remote Control 1 14...
Страница 19: ...Meanings of Symbols 1 15...
Страница 20: ...16...
Страница 21: ......
Страница 23: ...19...
Страница 45: ...41 Applicable in selected models only...
Страница 46: ...42...