KINO-KX SBC
Page 93
NOTE:
The Watchdog Timer is activated through software. The software
application that activates the Watchdog Timer must also deactivate it
when closed. If the Watchdog Timer is not deactivated, the system will
automatically restart after the Timer has finished its countdown.
EXAMPLE PROGRAM:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
;
MOV
AX, 6F02H
;setting the time-out value
MOV
BL, 30
;time-out value is 48 seconds
INT
15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP
EXIT_AP, 1
;is the application over?
JNE
W_LOOP
;No, restart the application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV
BL, 0
;
INT
15H
;
; EXIT ;
Содержание KINO-KX Series
Страница 2: ...KINO KX SBC Page II Revision Date Version Changes February 18 2021 1 00 Initial release ...
Страница 8: ...KINO KX SBC Page VIII F 1 ROHS II DIRECTIVE 2015 863 EU 97 F 2 CHINA ROHS 98 ...
Страница 12: ......
Страница 13: ...KINO KX SBC Page 1 Chapter 1 1 Introduction ...
Страница 17: ...KINO KX SBC Page 5 1 5 Dimensions The dimensions of the two models are listed below Figure 1 3 Dimensions mm ...
Страница 21: ...KINO KX SBC Page 9 Chapter 2 2 Unpacking ...
Страница 25: ...KINO KX SBC Page 13 Chapter 3 3 Connectors ...
Страница 51: ...KINO KX SBC Page 39 Chapter 4 4 Installation ...
Страница 63: ...KINO KX SBC Page 51 Chapter 5 5 BIOS ...
Страница 96: ...KINO KX SBC Page 84 Appendix A A Regulatory Compliance ...
Страница 98: ...KINO KX SBC Page 86 B Product Disposal Appendix B ...
Страница 100: ...KINO KX SBC Page 88 Appendix C C BIOS Menu Options ...
Страница 103: ...KINO KX SBC Page 91 Appendix D D Watchdog Timer ...
Страница 106: ...KINO KX SBC Page 94 Appendix E E Error Beep Code ...
Страница 108: ...KINO KX SBC Page 96 Appendix F F Hazardous Materials Disclosure ...