ID Swing Gate 2400
9
12 Close gate control
0~9
2
0: Start closing while ongoing passage 1: start closing at the end of
the passage
2: start closing after the passage
3-9: Additional delay (n-2 seconds) after passage is completed
13 Single motor mode
0~1
0
0: Double motor mode (for two-way passage). 1: Single motor mode
(for one-way passage).
15
Obstacle detection,
infrared anti-pinch
rebound
0~1
1
0: Obstacle detection => Gate stays in place. 1: Obstacle detection
=> gate opens fully again
16
Mechanical anti-pinch
sensitivity
1~9
5
The higher the value, the higher the sensitivity.
19
Power-off gate
opening direction
0~2
2
0: Open the gate to the left after power failure.
1: Open the gate to the right after power failure.
2: The system automatically selects the power-off gate opening
direction based on the current situation.
The gate opening direction can be referenced to the arrow direction
on the top light board.
22
Left and right infrared
effective signal delay
1~9
5
Time = parameter * 20 milliseconds (default 100ms)
27
Anti-pinch priority
setting
0~1
0
0: Fast passage mode, priority to open the gate, infrared anti-pinch
is invalid during the gate opening process, and the gate can be
opened when there is a signal from the left and right infrared;
1: Safe passage mode, priority to anti-pinch, infrared anti-pinch is
valid during the gate opening process, and the gate cannot be
opened when there is a signal from the left and right infrared.
32
Main motor sliding
compensation
0~9
0
If the switch gate panel cannot return to the starting position
immediately after the self-check is completed, the sliding
compensation can be increased appropriately.
33
Slave motor sliding
compensation
0~9
0